maintenance / troubleshooting
Replace the belt cover by inserting the end furthest from
the brush first. Then replace the front of the belt cover
before securing in place with the two screws (Fig.5/8).
6. Troubleshooting
WARNING: To reduce the risk of personal injury,
unplug the vacuum cleaner before performing
maintenance or troubleshooting checks.
PROBLEM: The cleaner won't run.
Cause:
Not properly plugged into electrical outlet.
Solution:
Plug in firmly.
Cause:
No electricity in electrical outlet.
Solution:
Check fuse or breaker.
Cause:
ON/off switch not turned on.
Solution:
Push on/off switch to ‘on’.
Cause:
Blown fuse/tripped breaker.
Solution:
Reset circuit breaker or replace fuse.
PROBLEM: Cleaner won’t pick up/loss of suction.
Cause:
Dirty water tank is full.
Solution:
Switch off and unplug cleaner. Empty dirty
water tank as shown in Section 4.
Cause:
Dirty water tank not installed correctly.
Solution:
Refer to page 9 for fitting information.
Cause:
Obstruction in hose/nozzle.
Solution:
Remove hose and clear obstruction.
Cause:
Broken or worn belt.
Solution:
Replace the belt. See page 10.
Cause:
Brushbar is worn.
Solution:
Replace the brush bar. See page 10.
PROBLEM: Dust escaping from the vacuum.
Cause:
Dirty water tank is full.
Solution:
Switch off and unplug cleaner. Empty dirty
water tank as shown in Section 4.
Cause:
Dirty water tank not installed correctly.
Solution:
Refer to page 9 for fitting information.
Cause:
Solution tank not installed correctly.
Solution:
Make sure the tank is securely locked in place
PROBLEM: Clean solution won’t dispense.
Cause:
Solution tank not installed correctly.
Solution:
Make sure the tank is securely locked in place.
Cause:
Solution tank empty.
Solution:
Refill tank. Refer to page 6 for instructions.
!
Fig.5/7
Fig.5/8
All manuals and user guides at all-guides.com