background image

IMPORTANT: Read this manual carefully before installing the fresh-r®!
Keep this manual for future use.

On-The-Wall

Installation manual

Содержание fresh-r On-The-Wall

Страница 1: ...IMPORTANT Read this manual carefully before installing the fresh r Keep this manual for future use On The Wall Installation manual ...

Страница 2: ...city supply and must be connected by a qualified electrician Other information relating to the target group can be found in chapter 2 The information in this manual is important for the correct and safe installation of the fresh r With the table of contents you ll be able to find the right information in the manual quickly This is the installation manual Besides this manual there is also an user m...

Страница 3: ... Specifications 23 11 Who can I contact for questions spareparts or more information 23 12 Warranty 23 13 Frequently asked questions 24 14 Declaration of conformity 26 15 Appendix 27 15 1 Technical drawings 27 15 1 1 fresh r 27 15 1 2 fresh r with rectangular duct on top 28 15 1 3 Outer wall template 29 15 2 Fresh air everywhere connect to your in house ventilation system 30 15 2 1 Rectangular duc...

Страница 4: ... may only be installed on a wall 2 Target group The manual describes how to install the fresh r The installation must be done by contractors who are familiar with local building regulations Connecting the fresh r to the mains electricity supply must be done by a qualified electrician 3 Symbols used in this manual 3 1 Safety symbols DANGER Indicates an immediate risk of irreversible injury or death...

Страница 5: ...pply in the distribution box before connecting the fresh r electrically The person responsible for installing the fresh r should be familiar with the local building regulations 5 Main components A B C D E F G H fig 1 Main components top side A ON OFF switch B Power connection wire C Unibody D Front door connected to the Unibody E Grilles F Grille cover G Grille assembly 2pcs H Duct pipes with EPP ...

Страница 6: ...level or another tool to check for a prefect vertical position Deburring or grinding tool such as a file EPP Glue and expanding foam 7 How to install the fresh r DANGER The person responsible for installing the fresh r should be familiar with the local building regulations Please follow steps 1 to 10 1 Check the contents 1 Cardboard wall cut drilling template 2 Grilles assembly 1 Front door 3 Bags...

Страница 7: ...e supplied See fig 3 and fig 4 Draw the holes To draw the holes do the following 1 Place the template against the outer wall make sure it s vertically leveled 2 Tape the template on the wall Use removable tape in the corners Make sure UP is visible and is pointing upwards 3 Mark the centres of the big holes by tracing the four notches around the hole Use a pencil and a ruler to make two crosses Th...

Страница 8: ... wall is well prepared 2 Remove dust and other materials from the holes 3 Get a duct pipe this is the blue PVC pipe with EPP cover this is a foam tube and try if it fits the holes The four corner holes To drill the four corner holes do the following 1 Check the dimensions as shown in fig 6 2 Drill the four corner holes Use a 8 mm masonry drill 3 Place plugs into the four corner holes You ll find t...

Страница 9: ...9 fig 6 Check the dimensions of the corner holes before drilling 243 mm 105 mm 111 mm 1055 mm ...

Страница 10: ... input fresh air to the total width of the wall D1 15 mm Tip Use a wide tape or two paper sheets taped together to mark the duct pipes and get a perpendicular cut 3 Cut the lower duct pipe output stale air to the total width of the wall s D1 55 mm 4 Deburr the duct pipes Use a deburring tool such as a file D1 D1 15 mm D1 55 mm fig 7 Determine D1 fig 8 Make the duct pipes to the correct size ...

Страница 11: ...moist indoor air may reach the cold ducts 1 Put PVC glue on the white ring which is located in the inside of the stale air output socket see fig 9 Do not put PVC glue on the freh air input tube fig 9 Put PVC glue in the stale air output socket on the white ring only 2 Place the duct pipes into the Unibody Make sure the lips are pointed towards the bottom side of the Unibody These are needed to mat...

Страница 12: ... 3 Put EPP glue on the Unibody around the PVC duct pipes fig 11 Put EPP glue on the Unibody around the PVC duct pipes 4 Place the EPP covers on the duct pipes fig 12 Place the EPP covers Epp glue Epp glue ...

Страница 13: ... upper duct pipe to the Unibody needs to be airtight because air leaks can create unwanted condensation fig 13 Put EPP glue around the edges of the covers 6 Cut the Epp covers They need to cover the whole duct pipe The lips need to extend beyond the covers fig 14 Cut the EPP covers fig 15 The lips need to extend beyond the covers Epp glue Epp glue ...

Страница 14: ... Make sure the expanding foam insulate the whole edge of the EPP covers in order to prevent air leaking regarding the inner wall fig 17 Put expanding foam around the edge of both EPP covers 3 Place the Unibody in vertical position and open the door as far as possible 4 Press the two storm flap levers to ensure they are open DON T remove the two middle bolts Remove the four corner bolts ...

Страница 15: ...e by two persons First read step 5 6 and 7 so you are well prepared Then perform the actions CAUTION Be carefull with the door Giving too much pressure can damage the door or it s hinges fig 19 Be carefull with the door DON T apply force to the the door when raising the fresh r ...

Страница 16: ... on the wall 6 The second person Mount the 6 x 120 screws in each corner of the Unibody 4 Use a screw driver CAUTION The ducts and the holes must have an air tight seal To establish this it s critical that all four screws are properly functioning Make sure the fresh r is pushed firmly to the wall when attaching it NOTICE When you are installing the fesh r everywhere now use the extract ducts to ma...

Страница 17: ...ionality DANGER Connecting the fresh r to the mains electricity supply must be done by a qualified electrician Risk for electric shocks or electrocution Turn off the mains electricity supply in the distribution box before connecting the fresh r electrically Do the following 1 Turn off the main electricity supply in the distribution box before attempting to wire in the fresh r 2 Make the electrical...

Страница 18: ...ning If not Check the main electricity supply If the product still does not work turn the unit OFF and contact your supplier 7 Place the grilles assembly find the content in Bag B Do the following 1 Mount the grilles on the outer face of the outside wall 2 Place the covers NOTICE The lip of the lower duct pipe should overlap with the edge of the grilles cover so condensate water is guided from the...

Страница 19: ...19 fig 25 Lip should overlap with the edge of the grilles ...

Страница 20: ...rease fan speed for approximately 5 seconds until you hear a beep Then wait 10 seconds 3 Press the lower button decrease fan speed for approximately 5 seconds until you hear a beep the WiFi chip is now in access point mode The following actions must be done with your smartphone laptop or tablet Do the following 4 Start your device and go to settings 5 Select WiFi 6 Select WiFly EZX XX from the lis...

Страница 21: ...ou can normally find it on a sticker on the router itself 12 Enter your WiFi passphrase wireless key also called password in the Passphrase box Tip Check the Show Passphrase to visually check that you entered the correct passphrase 13 Press save reboot NOTICE If the connection fails check the settings of your router Please make sure that the Wireless 2 4 Ghz configuration is set to mixed mode See ...

Страница 22: ...PVC Glue Page 11 step 1 Are the duct pipes sealed against the the EPP back cover Page 12 step 3 4 Are the duct covers sealed against the the EPP back cover Page 13 step 5 Are the duct pipes sealed against the inner wall Page 14 step 2 Are the storm flaps fully open Page 15 step 4 Are the duct pipes properly sealed at the outside wall Page 17 step 7 Does the unit sound normal Does the door open and...

Страница 23: ... kg Dimensions 1143 mm 300 mm 160 mm Capacity Automatic regulation upto 120m3 hr Continues heat recovery at sub zero temperatures Yes with automatic defrost mode Full automatic operation Self regulating flow control based on CO2 11 Who can I contact for questions spareparts or more information Vaventis Achteromstraat 8a 1381 AV Weesp support vaventis com T 31 294 261 171 www vaventis com 12 Warran...

Страница 24: ... supplier for details Can the fresh r be installed horizontally No the condensate will not be guided correctly contact your supplier for details Can the fresh r be mounted upside down No the condensate will not be guided correctly contact your supplier for details Where does the air enter the room From the bottom of the door Where is the air extracted from the room From the top of the door Why sho...

Страница 25: ...perate the unit On the control panel A for automatic You can increase or decrease the fan speed manually using the fan buttons Refer to the user manual Increase or lower fans speed via the fan buttons refer to user manual What does the smiley tell me They indicate the air quality refer to user manual Does the unit measure RH or CO Yes it measures both please refer to user manual What maintenance s...

Страница 26: ...p The Netherlands declare under our sole responsibility that the following product E quipment Air handling unit with heat recovery Brand name Vaventis Model type Fresh r is in conformity with the following Directives 2006 95 EC Low Voltage LVD the product bears the CE label 14 J van Beuzekom Managing Director Weesp August 1 st 2015 ...

Страница 27: ...27 15 Appendix 15 1 Technical drawings 15 1 1 fresh r Dimensions are in mm Dimensions in brackets are in inches ...

Страница 28: ...28 15 1 2 fresh r with rectangular duct on top Dimensions are in mm Dimensions in brackets are in inches ...

Страница 29: ...29 15 1 3 Outer wall template Dimensions are in mm Dimensions in brackets are in inches ...

Страница 30: ... everywhere to your in house extraction duct fig 26 Example of an extract duct connected to the top of the fresh r everywhere To make this connection three extract ducts can be used 100 3 937 204 8 032 60 2 362 Rectangular duct Rectangular right angle duct Rectangular to round duct It depends on the particular situation which extract ducts you need and how you make the connection Please refer to t...

Страница 31: ...ions are in mm Dimensions in brackets are in inches 100 3 937 204 8 032 60 2 362 15 2 2 Rectangular right angle duct dimensions 100 3 937 204 8 032 60 2 362 205 8 071 2 places 61 2 402 2 places 50 1 969 258 75 10 187 2 places 104 5 4 114 2 places ...

Страница 32: ...32 15 2 3 Rectangular ro round duct dimensions Dimensions are in mm Dimensions in brackets are in inches 120 4 724 220 8 661 126 4 961 ...

Страница 33: ...33 ...

Страница 34: ...34 ...

Страница 35: ...35 ...

Страница 36: ...www vaventis com 2015 by Vaventis B V All right reserved ...

Отзывы: