background image

OPERATING MANUAL 3300 DPF                                                                                V6.4/20-EN 

Page | 6 

Attention:  

Pay attention to a proper disposal of the residues, which arise 
during the maintenance and care.  
 

 

8.

 

Storage 

The compressed air tool must be stored under the following conditions:

 

 

If residual material is present, the pressure container must be emptied.

 

 

Carefully clean the pressure cup gun after each use. 

 

Store in a dry and dust-free place. 

 

Do not expose to liquids and/or aggressive chemicals. 

 

Keep out of the reach of children. 

 

9.

 

Troubleshooting 

In  the  event  of  any  malfunctions,  please  first  check  whether  sufficient  com-
pressed air is available and whether the spray material can still be processed. 

 

Gun  sprays messy

 

 

Possible cause:  Operating pressure too low, nozzles are dirty. 
Solution:  Increase operating pressure, clean nozzles.

 

 

Gun does not spray any material 

Possible cause: Riser pipe and/or nozzles are clogged. 
Solution:Clean clogged parts.

 

 

Air exits the spray nozzle even though the trigger is in its initial position.  

Possible cause:: Valve bolt is jammed.  
Solution: Pour oil onto the valve bolt and/or into the compressed air intake. 
Operate the trigger several times.    

 

Material exits the spray nozzle even though the trigger is in its initial posi-
tion. 

Possible cause: Nozzle needle is jammed / dirty.  
Solution:  Clean  the  nozzle  needle,  apply  oil  to  the  nozzle  needle  and/or 
slightly re-duce the pressure on the nozzle needle seal using a 9mm wrench. 
In order to ensure error-free use, a clamping effect on the nozzle needle seal 
must remain. Press the trigger several time.    
 

10.

 

 Warranty terms 

The basis for all warranty claims is the complete pressure cup gun and the proof 
of purchase. Damage caused by improper handling of the pressure cup gun is 
not covered by the warranty. 
If you have any questions, please indicate  the type description or  the article 
number of the pressure cup gun. 

 

In conformity with legal regulations, you receive a 24-month warranty on 
all products against material and manufacturing defects. 
 

Содержание 3300 DPF

Страница 1: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 1 Cleaning pressure cup gun 3300 DPF Art no 33140 33158 ...

Страница 2: ...ting manual with the pressure cup gun General notice This pressure cup gun was developed for certain applications We explicitly point out that this pressure cup gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation end of work 5 7 Maintenance a...

Страница 3: ...y included with 3300 DPF set Hose set 3900 WH 02 04 3 Intended use This pressure cup gun is a compressed air operated quality tool for professional use It is suitable for processing liquid media in the form of loose containers 4 Features The effectiveness of the 3300 DPF pressure cup gun is based on overpressure For this purpose pressure is built up in the pressure container by means of an air duc...

Страница 4: ...rom the compressed air connection before carrying out maintenance or repair work Only use original spare parts The maximum working pressure must not be exceeded see point 1 Technical data The working pressure must be adjusted via a filter pressure reducer Only use compressed air as energy source The compressed air connection may only be made via quick coupling When working with the pressure cup gu...

Страница 5: ...ced by the following factors Material quantity via stop screw nozzle needle Adjusting the intake pressure optional Distance between hand spray nozzle and object Angular position of the hand spray nozzle to the object End of work Vent the pressure container by turning the pressure container counterclockwise Disconnect the device from the compressed air supply after each use Empty the pressure conta...

Страница 6: ...n clogged parts Air exits the spray nozzle even though the trigger is in its initial position Possible cause Valve bolt is jammed Solution Pour oil onto the valve bolt and or into the compressed air intake Operate the trigger several times Material exits the spray nozzle even though the trigger is in its initial posi tion Possible cause Nozzle needle is jammed dirty Solution Clean the nozzle needl...

Страница 7: ... gun must be in its original condi tion 11 Address In case of service your sales representative is at your side or contact the follow ing address Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ f...

Страница 8: ...rdance with the above EC Directives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging to...

Страница 9: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 9 13 Notices ...

Страница 10: ...OPERATING MANUAL 3300 DPF V6 4 20 EN Page 10 14 Technical drawing ...

Страница 11: ...on 16 60 4100 364 O ring 5 x 1 mm 17 30 1421 012 Needle gland 18 60 4100 366 O ring 8 x 2 5 mm 19 30 1422 014 Nozzle head 20 20 1413 001 Quick coupling 21 See accessories list Cavity spray hose accessory 22 83313 O ring 15 x 2 mm 23 Adapter 3000 25 O ring 33 x 2 mm 26 10 2111 014 Cup holder 27 60 4100 344 U cup 12 x 18 x 4 5 x 1 6 28 60 4100 387 O ring 35 x 4 mm 29 30 83309 Fixing screw 31 10 4102...

Отзывы: