OPERATING MANUAL 3300 DPF V6.4/20-EN
Page | 6
Attention:
Pay attention to a proper disposal of the residues, which arise
during the maintenance and care.
8.
Storage
The compressed air tool must be stored under the following conditions:
•
If residual material is present, the pressure container must be emptied.
•
Carefully clean the pressure cup gun after each use.
•
Store in a dry and dust-free place.
•
Do not expose to liquids and/or aggressive chemicals.
•
Keep out of the reach of children.
9.
Troubleshooting
In the event of any malfunctions, please first check whether sufficient com-
pressed air is available and whether the spray material can still be processed.
•
Gun sprays messy
Possible cause: Operating pressure too low, nozzles are dirty.
Solution: Increase operating pressure, clean nozzles.
•
Gun does not spray any material
Possible cause: Riser pipe and/or nozzles are clogged.
Solution:Clean clogged parts.
•
Air exits the spray nozzle even though the trigger is in its initial position.
Possible cause:: Valve bolt is jammed.
Solution: Pour oil onto the valve bolt and/or into the compressed air intake.
Operate the trigger several times.
•
Material exits the spray nozzle even though the trigger is in its initial posi-
tion.
Possible cause: Nozzle needle is jammed / dirty.
Solution: Clean the nozzle needle, apply oil to the nozzle needle and/or
slightly re-duce the pressure on the nozzle needle seal using a 9mm wrench.
In order to ensure error-free use, a clamping effect on the nozzle needle seal
must remain. Press the trigger several time.
10.
Warranty terms
The basis for all warranty claims is the complete pressure cup gun and the proof
of purchase. Damage caused by improper handling of the pressure cup gun is
not covered by the warranty.
If you have any questions, please indicate the type description or the article
number of the pressure cup gun.
•
In conformity with legal regulations, you receive a 24-month warranty on
all products against material and manufacturing defects.