background image

OPERATING INSTRUCTIONS 2000 KS                                                                        V7.4/20-EN 

Page| 5 

Attention:  

Pay attention to a proper disposal of the residues, which arise 
during the maintenance and care.

 

 

 

8.

 

Storage 

The compressed air tool must be stored under the following conditions:

 

 

If residual material is present, store only upright! 

 

Carefully clean the spray gun after each use. 

 

Store in a dry and dust-free place. 

 

Do not expose to liquids and/or aggressive chemicals. 

 

Keep out of the reach of children. 

 

9.

 

Troubleshooting 

In all cases of malfunction, please first check whether there is sufficient com-
pressed air available, whether the spray material can still be processed, wheth-
er the expiry date has passed or whether the material has dried out. 

 

Gun sprays messy 

Possible cause: Plastic spray pipe, riser pipe or ventilation hole dirty. 
Solution: Clean parts.

 

 

Gun does not spray any material 

Possible cause: Riser pipe/plastic spray pipe clogged. 
Solution: Clean clogged parts.

 

 

Air escapes from the spray nozzle even though the trigger is in its initial 
position.

 

 

Possible cause: Valve bolt is jammed.

 

Solution: Pour oil onto the valve bolt and/or into the compressed air intake. 
Operate the trigger several times.   

 

 

10.

 

 Warranty terms 

The basis for all warranty claims is  the complete spray gun and the proof of 
purchase. Damage caused by improper handling of the spray gun is not covered 
by the warranty. 
If you have any questions, please indicate the type description or  the article 
number of the spray gun. 

 

In conformity with legal regulations, you receive a 24-month warranty on all 
products against material and manufacturing defects. 
 

Excluded from the warranty:   

 

Wear parts.  

 

Damage caused by improper use. 

 

Damage caused by lack of maintenance. 

 

Damage caused by dirt. 

Содержание 2000 KS

Страница 1: ...OPERATING INSTRUCTIONS 2000 KS V7 4 20 EN Page 1 Spray gun 2000 KS Art no 20001 20002 20004 ...

Страница 2: ...e always keep this operating manual with the spray gun General notices This spray gun was developed for specific applications We explicitly point out that this spray gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation 4 7 Maintenance and care...

Страница 3: ...ir stream is used which accelerates when the air nozzle flows through and thus generates negative pressure in the adjoining riser pipe The spray mass is thereby sucked in and sprayed out via the nozzle by the air flow 5 Safety instructions Protect yourself and the environment by taking appropriate precautions against the risk of accidents and observe the following instructions in your own interest...

Страница 4: ...as clean ing media must be disposed of in an environmentally friendly manner The disposal of the compressed air device must be carried out according to the valid legal regulations 6 Installation Screw in the supplied steel riser pipe hand tight Pierce the protective foil of the 1 litre can and dip the riser pipe into the spraying material Screw the 1 litre can into the plastic threaded cap of the ...

Страница 5: ... riser pipe or ventilation hole dirty Solution Clean parts Gun does not spray any material Possible cause Riser pipe plastic spray pipe clogged Solution Clean clogged parts Air escapes from the spray nozzle even though the trigger is in its initial position Possible cause Valve bolt is jammed Solution Pour oil onto the valve bolt and or into the compressed air intake Operate the trigger several ti...

Страница 6: ... your sales representative is at your side or contact the following address Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ from the original We assume no liability for printing errors ...

Страница 7: ...formity with the above EC Di rectives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging ...

Страница 8: ...0 029 Lock washer 5 80158 Valve bolt 6 O ring 1 5 x 0 75 mm 7 Valve seal 8 60 3103 003 Spring for valve 9 60 4100 062 O ring 8 x 1 mm 10 30 1120 002 Locking screw 12 30 1422 008 Air nozzle 2 5 mm 17 40 4428 001 Plastic spray pipe 2900 KS 21 40 4112 010 Threaded cap 21 A Ventilation hole 22 30 1432 018 Fixing screw m 10 x 1 mm 23 60 3129 001 Riser pipe 253 mm 24 Connection thread ...

Отзывы: