![Vauconsant A63208VRP Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/vauconsant/a63208vrp/a63208vrp_user-manual_856042009.webp)
USER MANUAL
Vauconsant SA, all rights reserved A632xxVRP -rev0-ENG, 26/10/2010 -
9
-
Maintenance
Always remember to
switch off
the appliance by opening the fuse holder before any
maintenance operations.
•
Features:
Power
Reference
Capacity
Refrigeration
Electric
A63208VRP
2GN
800 W
1000 W
A63213VRP
3GN
1185 W
1450 W
A63215VRP
4GN
1185 W
1900 W
A63219VRP
5GN
1440 W
2350 W
Evaporation
well option
+ 750 W
•
Procedures:
Every 4 months, check that the condenser is not blocked and clean it properly.
Every year, check:
o
That the condenser ventilator works properly
o
That the evaporator ventilators work properly
o
the jacks move up and down properly
The installer should check electric connections when commissioning the unit then once a year.
Any maintenance operations should be done by a professional.