Technical information VERSO VA-IP2 – V1.0 

 

 

p.11/13 

 

 

INSTALLATION OF VISOR (SOFTWARE) DONGLE 

 

To use the VISOR software, you must, in certain cases (see following table), install a dongle on 
your unit. 

 

Use of the dongle 

Number of readers in the installation 

Software 

Dongle 

Up to 100 readers 

VISOR-100 Comes 

standard, FREE 

Dongle required 

Up to 840 readers 

VISOR-840, 

available as an 

option 

Dongle required 

 

Installation of dongle: 

with the power off

, install the dongle as shown below: 

 

 

 

 

 

To confirm proper operation, VISOR shows the version being used at the bottom of the main 
screen. Your unit must be rated for the dongle to be detected. 

If you do not have the correct dongle for your installation type, your units will be displayed “rated” 
in the equipment list but no updates or event collection will be performed. 

Содержание VA-IP2

Страница 1: ...Technical Information VA IP2 VERSO 220...

Страница 2: ...N 5 CONNECTING A DEVICE USING THE wiegand or clock data protocol 6 CONNECTING V EXT4 AND V EXT4 220 modules 7 CONNECTING A POWER LOSS BOLT AND AN ELECTROMAGNETIC DOOR LOCK OPERATING ON POWER LOSS 8 CO...

Страница 3: ...hased a VERSO VA IP2 unit manufactured by the French company Vauban Systems exclusively distributed by Eos Australia for the Australian and New Zealand markets We thank you for your interest in our pr...

Страница 4: ...ordance with the instructions for Level 2 protected environment of standard NF EN 61000 4 4 o This product must be installed by an approved company Incorrect installation and use may result in electri...

Страница 5: ...2V 1A 24V 2 VERSO 220 Weight with housing 4 kg Housing dimensions 330 x 275 x 80 mm Operating temperature 20 C to 50 C Integrated 220V power supply Output voltage 12V Maximum output current F2 5A F1 6...

Страница 6: ...higher Note Each reader can have different technology e g Reader 1 using Wiegand Reader 2 using Clock Data Warning If you use an external power supply for your proximity readers take care to connect...

Страница 7: ...erminals on the V EXT4 modules to connect an RS485 bus Information 2 conductors 2 pairs recommended Max distance 750 m Cable type 0 6 mm SYT recommended Warning Do not install the cables near other hi...

Страница 8: ...ay interfere with proper system operation due to back currents it is imperative to use and connect the anti back current diodes supplied with the unit in compliance with the cabling diagram above Even...

Страница 9: ...er system operation due to back currents it is imperative to use and connect the anti back current diodes supplied with the unit in compliance with the cabling diagram above Even when using an additio...

Страница 10: ...fferent IP address you can use the Automatic detection menu in VISOR To do this proceed as follows After having created your installation on first start up VISOR offers to create a new unit Click on t...

Страница 11: ...andard FREE Dongle required Up to 840 readers VISOR 840 available as an option Dongle required Installation of dongle with the power off install the dongle as shown below To confirm proper operation V...

Страница 12: ...Technical information VERSO VA IP2 V1 0 p 12 13 FUNCTIONS OF THE TERMINALS Reset switch 1 Reset switch 2 Ethernet network RS485 extension bus...

Страница 13: ...55 0 Turn off the power Hold the switch down while turning the power back on Wait until the relays engage about 20 seconds holding the switch down Release the switch Use this switch to clear the unit...