10. Recognition of Position
The DTSG 4 may be built in various positions. To keep the display legible if the build-in position has
been changed, this position is queried by an internal sensor. The display will then be rotated by the
device in to remain legible. The key functions are not exchanged, they keep their meanings.
The position recognition may be influenced by coding bridges on the circuit board. The following
settings are possible:
i)
automatic recognition of position
ii)
normal position (mains switch at the upper right side)
iii)
“upside-down” position (mains switch at the lower left side)
The position is only queried during the switch-on operation, a change in position during the operation will
not be considered.
11. Light barrier at Conveyor end
You may connect a light barrier at the conveyor end to the connection clamp 19. When the light barrier
is active, the motor stops. The LED display monitors the message „LS Band“. The input may be
switched with the jumper J7 for usage of PNP and NPN light barriers (see page 21). Per default this
input is set for usage of PNP light barriers.
12. Clear function
To e.g. clear a transport band, you may connect a caliper or a light barrier to the connection clamp 20.
the motor runs as long as the caliper or the light barrier is used. The input may be switched with the
jumper J6 for usage of PNP and NPN light barriers (see page 21). Per default this input is set for
usage of PNP light barriers
13. R
eversible function
If a pulse occurs on terminal 20, the conveyor belt runs backward as long as the pulse is
present. The display shows "r RUN" appears.
After decrease of the pulse, the conveyor belt
is running by an adjustable time (menu item nL) again in the forward direction. In the display
"n RUN" will appear, and the word "RUN" indicator flashes. After this time, the device starts
from the beginning. The function is in both operating modes with / without ext. Trigger