Installation, Operating & Maintenance Instructions 

Series 75.2, DN 40 (I.D. 1 ½”)

 

 

 

 

VAT Vakuumventile AG, CH-9469 Haag, Switzerland 

Tel ++41 81 771 61 61  Fax ++41 81 771 48 30  Email 

[email protected]

  

www.vatvalve.com 

207088EB

 

2005-04-28 

9/12 

 

 

4 Trouble 

shooting 

 
Failure Check  Action 
Valve does not close/open  

Power available?  

Check Power supply 

 

Commpressed air available?  

Check compressed air 
connection/pressure 

Leak at the gate  

Correct compressed air pressure? 

Check compressed air 
connection/pressure  

  Clean 

valve 

seat 

 

 

 

Clean gate seal  

  Replace 

gate 

seal 

Leak at the valve body  

Flange seal leaktight? 

Check flange seal 

 

Bonnet seal leaktight? 

Check bonnet seal  

 

Screws at bonnet tightened?  

Check closing torque of bonnet srews 

 
If you need any further information, please contact one of our service centers. You can find the addresses on our website: 
http://www.vat.ch

 

 

 
 
 

Maintenance & repairs 

 
 
Under clean operating conditions, the valve does not require any maintenance during the specified cycle life. 
Contamination from the process may influence the function and requires more frequent maintenance. 
 
Before carrying out any maintenance or repairs, please contact VAT. It has to be individually decided whether the 
maintenance/repair can be performed by the customer or has to be carried out by VAT. The fabrication number on the 
valve 
 

 

made in Switzerland 
Fabrication No.: 

patented 

. .

 

752. . – . . . . – . . . . / . . . . 

A – . . . . . . 

Fabrication num ber 

 

 
has always to be specified.  
 
All supplies (e. g. compressed air, electrical power) must be disconnected for removal/installation of the valve from/into 
the system and for maintenance work. 
 

 

Even with disconnected supply, loaded springs and/or air cushions in cylinders can be potential hazards. 

 

 

 

Keep fingers and objects away from the valve opening! 

 
Products returned to VAT must be free of harmful substances such as e.g. toxical, caustic or microbiological ones. If 
products are radioactively contaminated, fill in the VAT form «Contamination and Radiation Report» and send it with the 
product. The form is available at VAT. The maximum values indicated in the form must not be exceeded. 

Содержание 75232-CE44 Series

Страница 1: ...label below or similar made in Switzerland Fabrication No patented 752 A Fabrication number Explanation of symbols Read declaration carefully before you start any other action Keep body parts and obje...

Страница 2: ...2 Installation into the system 4 2 2 1 Admissible forces 4 2 3 Connections 5 2 3 1 Compressed air connection 5 2 3 2 Electrical connection 6 3 Operation 7 3 1 Normal operation 7 3 2 Operation under i...

Страница 3: ...ure range 1 10 10 mbar to 1 2 bar abs Differential pressure on the gate 1 2 bar in either direction Max differential pressure at opening 30 mbar 1 bar with reduced cycle life Cycles until first servic...

Страница 4: ...e is lifted out of the box and handled afterwards 2 2 Installation into the system Tighten mounting screws of the flanges uniformly in crosswise order Observe the maximum torque of 9 Nm 6 5 lbf ft for...

Страница 5: ...for USA Compressed air pressure min max overpressure 4 5 7 bar 65 100 psi Use only clean dry or slightly lubricated air Commercially available water separators and filters have to be installed Compre...

Страница 6: ...into the vacuum system moving parts cannot be touched Electrical connection between fast closing valve and controller is performed by a single connection cabel according to the following drawing Befo...

Страница 7: ...te system is described in a separate manual The valve is closed and opened by compressed air The valve is kept in the open position by a latch in the actuator The cylinder is permanently maintained un...

Страница 8: ...alve is in undefinied position 2 Then remove the screws as it is shown in pic 1 3 Now it is possible to remove the trigger unit pic 2 4 To assemble the trigger unit after the bake out you have to proc...

Страница 9: ...e any maintenance during the specified cycle life Contamination from the process may influence the function and requires more frequent maintenance Before carrying out any maintenance or repairs please...

Страница 10: ...osition Attention Bordering of 2 bore holes must be on the body side 10 Insert actuator gate assembly carefully At first insert two screws 28 19 and tighten them slightly only at both centering holes...

Страница 11: ...ating Maintenance Instructions Series 75 2 DN 40 I D 1 VAT Vakuumventile AG CH 9469 Haag Switzerland Tel 41 81 771 61 61 Fax 41 81 771 48 30 Email reception vat ch www vatvalve com 207088EB 2005 04 28...

Страница 12: ...foregoing warranty shall not apply to any product or component that has been repaired or altered by anyone other than an authorized VAT representative or that has been subject to improper installation...

Отзывы: