VAT 75232-CE44 Series Скачать руководство пользователя страница 3

 

Installation, Operating & Maintenance Instructions 

Series 75.2, DN 40 (I.D. 1 ½”)

 

 

 

 

VAT Vakuumventile AG, CH-9469 Haag, Switzerland 

Tel ++41 81 771 61 61  Fax ++41 81 771 48 30  Email 

[email protected]

  

www.vatvalve.com 

207088EB

 

2005-04-28 

3/12 

 

Use of product 

 
 
Use product for clean and dry indoor vacuum applications under the conditions indicated in chapter «Technical data» only! 
Other applications are only allowed with the written permission of VAT. 
 
 
 

1.1 Technical 

data 

 
Leak rate 

- Body 

<

 5 

. 

10

-10 

mbar ls

-1

 

- Seat 

<

 1 

. 

10

-9 

mbar ls

-1

 

 

Molecular flow conductance 

160 ls

-1

  

 
Pressure range 

. 

10

-10  

mbar to 1,2 bar (abs) 

 
Differential pressure on the gate 

1,2 bar in either direction 

 
Max. differential pressure at opening 

30 mbar (1 bar with reduced cycle life) 

 
Cycles until first service 

2000 under clean operating conditions   

 

   
Bake-out temperature 

  - Valve 

200°C (Trigger unit dismantled)  

  - Actuator 

  50°C 

 
Temperature difference seat/gate 

<

 

40°C 

 
Heating and cooling rate 

<

 80°C h

-1

 

 
Material 

  - Body 

1.4301, AISI 304 

  - Mechanism 

1.4310, AISI 301 

- Bellows 

AM350, AISI 636 

 
Seal 
    - Bonnet 

metal 

    - Gate 

Viton 

 
Mounting position 

any 

 
Electrical connection 

12-pole plug 

 
Position indicator: contact rating 

5A/250 V AC, 3A/50 V DC 

 
Compressed air connection 

1

/

8

“ (

1

/

8

“ NPT for USA) 

 
Compressed air pressure (overpressure) 

4 – 5 bar / 60 – 70 psig 

 
Volume of air cylinder 

0.2 l / .007 ft

3

 

 

Содержание 75232-CE44 Series

Страница 1: ...label below or similar made in Switzerland Fabrication No patented 752 A Fabrication number Explanation of symbols Read declaration carefully before you start any other action Keep body parts and obje...

Страница 2: ...2 Installation into the system 4 2 2 1 Admissible forces 4 2 3 Connections 5 2 3 1 Compressed air connection 5 2 3 2 Electrical connection 6 3 Operation 7 3 1 Normal operation 7 3 2 Operation under i...

Страница 3: ...ure range 1 10 10 mbar to 1 2 bar abs Differential pressure on the gate 1 2 bar in either direction Max differential pressure at opening 30 mbar 1 bar with reduced cycle life Cycles until first servic...

Страница 4: ...e is lifted out of the box and handled afterwards 2 2 Installation into the system Tighten mounting screws of the flanges uniformly in crosswise order Observe the maximum torque of 9 Nm 6 5 lbf ft for...

Страница 5: ...for USA Compressed air pressure min max overpressure 4 5 7 bar 65 100 psi Use only clean dry or slightly lubricated air Commercially available water separators and filters have to be installed Compre...

Страница 6: ...into the vacuum system moving parts cannot be touched Electrical connection between fast closing valve and controller is performed by a single connection cabel according to the following drawing Befo...

Страница 7: ...te system is described in a separate manual The valve is closed and opened by compressed air The valve is kept in the open position by a latch in the actuator The cylinder is permanently maintained un...

Страница 8: ...alve is in undefinied position 2 Then remove the screws as it is shown in pic 1 3 Now it is possible to remove the trigger unit pic 2 4 To assemble the trigger unit after the bake out you have to proc...

Страница 9: ...e any maintenance during the specified cycle life Contamination from the process may influence the function and requires more frequent maintenance Before carrying out any maintenance or repairs please...

Страница 10: ...osition Attention Bordering of 2 bore holes must be on the body side 10 Insert actuator gate assembly carefully At first insert two screws 28 19 and tighten them slightly only at both centering holes...

Страница 11: ...ating Maintenance Instructions Series 75 2 DN 40 I D 1 VAT Vakuumventile AG CH 9469 Haag Switzerland Tel 41 81 771 61 61 Fax 41 81 771 48 30 Email reception vat ch www vatvalve com 207088EB 2005 04 28...

Страница 12: ...foregoing warranty shall not apply to any product or component that has been repaired or altered by anyone other than an authorized VAT representative or that has been subject to improper installation...

Отзывы: