![VAT 570 Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/vat/570-series/570-series_installation-operating-and-maintenance-instructions_855884018.webp)
INSTALLATION
Series 570
18/36
Edition 14.02.2019
215086EG
Position indicators for max. 200°C and 300°C
contact rating
≤
50 V AC / DC;
≤
1 A
Single position indicator (option)
Double position indicator (option)
3
1
2
4
6
5
Lo
Lg
3
1
2
4
6
5
Lo
Lg
3
1
2
4
6
5
Lo
Lg
Lo = position indicator «open»
Lg = position indicator «closed»
Lo = position indicator «open»
Lg = position indicator «closed»
Position indicator for max. 80°C
contact rating
≤
50 V AC / DC;
≤
1.2 A
Common plug for pos. indicator and solenoid, pos. indicator with make contact switches
(option)
1
2
3
4
5
6
Lg
Lo
p owe r
4
3
5
6
2
1
MV
Lo = position indicator «open»
Lg = position indicator «closed»