INSTALLATION
Series 570
10/36
Edition 14.02.2019
215086EG
4
Installation
WARNING
Unqualified personnel
Inappropriate handling may cause serious injury or property damage.
Only qualified personnel are allowed to carry out the described work.
WARNING
Heavy weight
Physical overstraining.
Use a crane to lift the product.
4.1
Unpacking
Handling of the valve must take place under clean conditions normally observed in good
vacuum practice. The valve may only be touched with clean gloves. After the protective
covers have been removed, the sealing surfaces of the flanges have to be cleaned carefully
with alcohol. The screws of the flanges have to be tightened uniformly in diagonal crosswise
order. Determine that the valve and existing plumbing in the vacuum system will be
adequately supported.
•
Make sure that the supplied products are in accordance with your order.
•
Inspect the quality of the supplied products visually. If it does not meet
your requirements, please contact VAT immediately.
•
Store the original packaging material. It may be useful if products must be
returned to VAT.
Open the plastic bag protecting the valve only at the points where you need
access to the eyebolts (1) for fastening the crane hooks; see below. Keep
valve in the plastic bag until it is being installed into the system.