3 Operation
3.1 Normal
operation
Opening of closed valve
- without
solenoid:
•
before valve is opened
⎯
supply air pressure in closing direction
•
air supply to connection «open»
•
air release through connection «closed»
- with standard solenoid:
•
supply specified control voltage to the coil
- with impulse solenoid:
•
supply an impulse of specified control voltage to the coil for opening (pulse duration min. 50 ms)
-
with radiation resistant solenoid:
•
supply specified control voltage to the solenoid coil „open“ and coil „close“.