Installation, Operating & Maintenance Instructions
Series 29, DN 25 - 50 (I.D. 1" - 2")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
257676ED
2006-05-11
8/13
3 Operation
3.1 Normal
operation
Valve is closed by a spring (NC)
Valve is opened pneumatically
3.2 Operating
states
- No compressed air pressure:
Valve is closed
- Compressed air pressure to «S»: Bypass (soft-pump opening) is open, main valve is closed
- Compressed air pressure to «M»: Main valve is open
3.3 Operation under increased temperature
See «1.1 Technical data»
3.4 Behavior in case of compressed air pressure drop
Valve closed: Valve remains closed and leaktight
Valve open: Valve closes leaktight
3.5 Behavior in case of power failure
Valve with solenoid:
Valve closes leaktight with of a spring
Valve without solenoid: Behavior is undefined — depending on the customer’s installation
3.6 Adjustment of the soft-pump opening (intermediate position)
The compressed air pressure
at «M» and «S» must be
switched off.
The rod can be turned to the
desired position with an Allen
wrench (Allen key).
At the lowest scale value, the
conductance is minimal. By
turning the rod counter-
clockwise the conductance of
the soft-pump opening
increases. At the highest scale
value, the conductance is
maximal.
conductance diagram
DN40
DN25
DN50
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
11.00
12.00
13.00
14.00
0
1
2
3
4
5
6
7
8
9
10
soft pump position
c
onduc
ta
n
c
e
[
l/
s
] a
t
1
ba
r