Control Box cover removal and replacement
Removal
1) Disconnect Switch MUST be in the OFF position to remove control box cover.
2) Remove all sheet metal screws.(5 on the front, 2 on the top. Use a flat blade screw driver or 1/4” nut driver)
-Control box cover is “hooked” on the top and bottom
3) Pull the bottom of control box towards you slightly to unhook.
4) Lift up slightly, to unhook top of cover, and pull straight off.
Note: Cover cannot be removed with the disconnect in the ON position. The handle and shaft are keyed
to prevent this.
Installation is the reverse of Removal. Be sure to leave the disconnect in the OFF position for correct
alignment to the handle.
ONLY QUALIFIED TECHNICIANS SHOULD OPERATE/TEST CONTROL BOX COMPONENTS UNDER POWER
Main Power Switch:
Disconnects ALL power to the internal components
(Disconnect Switch) to allow safe access to the inside
of the control box. Power Lights are wired to the output
side of the Disconnect Switch, meaning it is only safe
to enter the control box when the Power lights are
NOT illuminated.
CPC Connector
(Motor)
Incoming Power
Controls
(2of2)
Pg. 13