Red Pilot Light out
Loose connections
Customer power failed or outlet failed
Controller bad
Check connections
Check power at main disconnect
Replacement controller
Red Light on
Loose connections
Bad controller
Bad Heater
Check connections
Replace controller
Replace Heater
Heat not cycling on
and off
Bad controller
Replace controller
Possible Cause
Solution
IMPORTANT
Turn off and lock out power at the main disconnect before entering
any part this equipment . Do Not operate with any covers or guards removed.
Troubleshooting
Please set controller to at least “5” for diagnostics.
This view of the control
assembly “upside down” is
to show you the speed pot
adjustments on the bottom
side of the controller.
Pot near the white wires LOW SPEED.
Pot near the blue wires HIGH SPEED.
Setting the low speed pot adjustment:
(small screw driver with plastic handle is needed)
Turn the speed pots clockwise to increase the speed and counterclockwise to decrease. The low speed pot should be set so
the belt (or sprocket) moves very slow at the lowest setting on the controller, just before the controller is clicked in the off
position. The high setting is set so 90 VDC is the maximum voltage to the motor, a volt meter is needed for the high speed
adjustment. The control assembly should be placed on a bench so the speed pots are up and accessible.
Caution: Do not to touch the open wires around the controller and the fuse holder.
Belt Speed Controller adjustment
Motor still turning
Broken chain drive
Loose sprocket set screws
Replace chain & worn sprockets
Tighten sprocket set screws
Motor & drive pulley are turning
Obstruction in belt path
Belt loose
Clear jam
Tighten belt
Possible Cause
Solution
Belt Stopped
No Heat