7 / 9
To set the tilt to inversion
Press the MENU until it shows RTOF
Use the UP/DOWN buttons until it shows RTON, press ENTER to confirm.
Display inversion
Press the MENU until it shows RDOF.
Use the UP/DOWN buttons until it shows RTON, press ENTER to confirm.
Default setting
Press the MENU until it shows DFON.
press ENTER to confirm
DMX mode
This mode allows the unit to be controlled by any universal DMX controller.
The default mode for the fixture is DMX.
5. Technical Data
Voltage
230V 50Hz
Fuse
5A,
Ф
5×20mm,
Lamp resource
White LED , life is 50,000 hours
Pan
630°,16bit fine
Tilt
270°,16bit fine
Max temperature
104°F(40°C)
Date input/output
3pin XLR-connector
Size
260 ×260×350mm(L×W×H)
N.W
7.0kg