19.0” C1-D2 Compliant Panel Mount PC
486-0032-0-00
4
Explosion Hazard - Substitution of components may impair suitability for hazardous locations.
Any Equipment or associated cabling connected to this device must be non-incendive and/or
suitable for the Class 1, Division 2 area in which it is to be installed.
Hazardous Locations:
This equipment is suitable only for the locations specified on the product nameplate, specifically:
Class I, Division 2 Groups A, B, C, D
Non-hazardous
locations
The following statement applies to use in hazardous locations:
WARNING! Explosion Hazard
Substitution of components may impair suitability for hazardous locations.
Do not disconnect equipment unless power has been switched off and area is
known to be non-hazardous.
Do not connect or disconnect components unless power has been switched off.
All wiring must comply with N.E.C. articles 501-4(b), 502-4(b), 503-4(b) as
appropriate.
Peripheral equipment must be suitable for the location in which it is used.
All hazardous-location equipment must be mounted in an enclosure that is
suitably designed or rated for those specific environmental conditions that will be
present, and designed to prevent personal injury resulting from accessibility to live
parts.
This equipment has an operating temperature code of T4 when operating in a 60`C (140`F) ambient
environment. Do not install this product in environments where atmospheric gases have an ignition
temperature of less than 135`C (275`F).