background image

 

POWX910 

EN

 

Copyright © 2017 VARO 

P a g e

 | 

3

 

www.varo.com 

 

Hook the lower pivoting arm (7) on the hinge pin of the lower support and secure it by 
putting a large cotter pin (8) through the hole of the pin.  

 

Attach the loose part of the support arm (5) to the lower pivoting arm (7) by using an M12 
x 70 mm bolt (10), an M12 nut, a Ø 12 mm spring washer and a Ø 12 mm flat washer 
(pos. B). 

6  USE 

 

Before being taken into use, all components must be inspected. The vertical support pillar 
must be robust. The components of the pivoting arm must be undamaged and free of 
cracks. The support arms must be firmly attached. 

 

The supporting pillar must be in a good vertical position. The cable will only be correctly 
wound up on the attached winch, when the pivoting arm is located in a good horizontal 
position. 

 

The maximum load amounts to 600 kg at a distance of 750 mm relating to the vertical 
support pillar. For lifting this load, use the pivoting arm that has been installed as 
described above. 

 

Attention: With POW903 this pivoting arm cannot handle the double capacity of up to 800 
kg. 

 

For lifting loads with a maximum of 300 kg  (POW900 or POW901 and POW902 without 
double capacity), one can use the pivoting arm up to 1100 mm. Attach both parts of the 
arm to one another, by inserting a M12 x 70 mm bolt (10) in the second hole (pos. C) in 
the extendable part (9). Attach the M8 x 60 bolt (11) with an M8 nut, Ø8 mm spring washer 
and Ø8 mm flat washer in the first (smaller) hole of the extendable part (pos. A); this 
prevents the hoist from slipping off the support arm during use. 

 

The load may never exceed the maximum permitted value. 

 

Standing under a pivoting arm under load is not permitted. 

 

Caution: The provided rubber saddles (12) serve as adapters, for attaching the hoist to the 
extendable pivoting arm. The brackets themselves are delivered as part of the electrical 
hoists. They are not part of the components of this pivoting arm.  

 

Before use, first of all a lifting test and a pivoting test without load have to be performed. In 
the further course of the test the load should be increased evenly step by step. After this 
test, the required torque of 70 Nm for the mounting bolts has to be checked. 

7  INSPECTION AND MAINTENANCE 

 

Regularly inspect the supporting pillar. It must be solidly attached and may not be bent. 
Also check the rigidity and check that the supporting pillar still stands in a proper vertical 
position. 

 

Regularly check the components of the pivoting arm. It may not be damaged (dents, 
cracks, etc). 

 

Check all connections (bolts/nuts). They must be properly tightened. 

 

A defective pivoting arm is not repairable - it must be replaced immediately. 

 

The load may never exceed the maximum allowed values.  

 

It is not allowed to stand under the pivoting arm when this component is under load. 

 

It is strictly forbidden to lift a load simultaneously with 2 hoists. 

 

It is not allowed to lift up people with this hoist.  

 

Helpers and children should be kept away from the working area, when this tool is in use. 

 

Inexperienced persons may not operate this tool.  

8  TECHNICAL DATA 

Max. load at 750 mm 

600 kg 

Max. load at 1150 mm 

300 kg 

Rotation 

50° to the left and 50° to the right 

Отзывы: