background image

 

POWX1730 

EN

 

Copyright © 2015 VARO 

P a g e

 | 

8

 

www.varo.com 

8.4 

Storage 

I mportant! Pull the mains plug out of the socket and ventilate the appliance 
and all connected pneumatic tools. Switch off the compressor and make 
sure that it is secured in such a way that it cannot be started up again by 
any unauthorized person. 

Important! Store the compressor only in a dry location which is not 
accessible to unauthorized persons. Always store upright, never tilted! 

9  TECHNICAL DATA 

Type 

POWX1730 

Rated voltage

 

230V

 

Rated frequency 

50Hz 

Rated Power 

1100W / 1,5 pk 

Rotation speed 

3400 min

-1

 

Rated Pressure 

8 bar / 116PSI 

Tank capacity 

24 l 

Air debit (capacity) 

180 l/min 

Weight 

20 kg 

10 NOISE 

Noise emission values measured according to relevant standard. (K=3) 
Acoustic pressure level LpA 

77 dB(A) 

Acoustic power level LwA 

97 dB(A) 

ATTENTION! Wear hearing protection when sound pressure is  
over 85 dB(A). 

11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES 

FAULT 

CAUSE 

REMEDY 

The compressor 
does not start 

1. No supply voltage 

1. Check the supply voltage, the power 
plug and the socket-outlet. 

2. Insufficient supply 
voltage 

2. Make sure that the extension cable is 
not too long. Use an extension cable with 
large enough wires. 

3. Outside temperature 
is too low 

3. Never operate with an outside 
temperature of below +5°C. 

4. Motor is overheated 

4. Allow the motor to cool down. If 
necessary, remedy the cause of the 
overheating. 

The compressor 
starts but there is 
no pressure 

1. Leak in the non-return 
valve 

1. Replace the non-return valve 

2. The seals are 
damaged. 

2. Check the seals and have any 
damaged seals replaced by a service 
center 

3. The drainage screw 

3. Tighten the screw by hand. Check the 

Содержание POWERPLUS POWX1730

Страница 1: ...lasting guns 5 5 2 Safety information for paint spraying 5 5 3 Operating pressure vessels 6 6 POINTS TO NOTE WHEN SETTING UP THE COMPRESSOR 6 7 ASSEMBLY AND STARTING 6 7 1 Fitting the wheels 3 6 7 2 Fitting the supporting foot 4 6 7 3 Voltage 6 7 4 On Off switch 8 7 7 5 Adjusting the pressure Fig 2 7 7 6 Setting the pressure switch 7 8 CLEANING AND MAINTENANCE 7 8 1 Cleaning 7 8 2 Condensation wat...

Страница 2: ...POWX1730 EN Copyright 2015 VARO P a g e 2 www varo com 13 ENVIRONMENT 9 14 DECLARATION OF CONFORMITY 10 ...

Страница 3: ...packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packing materials are no to...

Страница 4: ...ing pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual curren...

Страница 5: ...hese instructions and in the manner intended for the particular type of power tool taking into account the working conditions and the work to be performed Use of the power tool for operations different from intended could lead to a hazardous situation 4 5 Service Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of th...

Страница 6: ...e then please contact the customer service workshop 6 POINTS TO NOTE WHEN SETTING UP THE COMPRESSOR Examine the machine for signs of transit damage Report any damage immediately to the company which delivered the compressor The compressor should be set up near the working consumer Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the ...

Страница 7: ...sure We recommend that you clean the appliance immediately after you use it Clean the appliance regularly with a damp cloth and some soft soap Do not use cleaning agents or solvents these may be aggressive to the plastic parts in the appliance Ensure that no water can get into the interior of the appliance You must disconnect the hose and any spraying tools from the compressor before cleaning Do n...

Страница 8: ... standard K 3 Acoustic pressure level LpA 77 dB A Acoustic power level LwA 97 dB A ATTENTION Wear hearing protection when sound pressure is over 85 dB A 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES FAULT CAUSE REMEDY The compressor does not start 1 No supply voltage 1 Check the supply voltage the power plug and the socket outlet 2 Insufficient supply voltage 2 Make sure that the extension cab...

Страница 9: ...time no claim can be made on the warranty if the damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fluid permeation excessive dust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the ins...

Страница 10: ...n of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2004 108 EC 2006 42 EC 2000 14 EC Annex VI LwA 94dB A 97dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN5501...

Отзывы: