POWXG9025
EN
Copyright © 2014 VARO
P a g e
|
11
www.varo.com
13 TROUBLE SHOOTING
SYMPTOM
CAUSE
RECOMMENDED ACTION
Machine refuses to
start
Machine not
plugged in
Plug in machine.
Defective socket
Try another socket.
Defective extension
cable
Try without the extension cable.
Fluctuating pressure
Pump is sucking air
Check that hoses and connections are
airtight.
Valves dirty, worn
out or stuck
Contact your nearest service centre
Water supply not
sufficient
Increase water pressure, check for blockage
of garden hose and/or change to bigger hose.
Pump seals worn
Contact your nearest service centre
Machine stops
Incorrect mains
voltage
Check that the mains voltage corresponds to
specification on the name plate
Thermal sensor
activated
Leave the machine for 5 minutes to cool down
Nozzle partially
blocked
Clean the nozzle with a needle and by
spraying water backwards through the nozzle
Amperage increase
Try without the extension cable.
Machine pulsating
Air in inlet
hose/pump
Allow machine to run with open trigger until
regular working pressure resumes.
Inadequate supply
of mains water
Increase water pressure, check for blockage
of garden hose and/or change to bigger hose.
Nozzle partially
blocked
Clean the nozzle with a needle and by
spraying water backwards through the nozzle
Water filter blocked
Clean the filter
Hose kinked
Straighten out hose.
Machine often starts
and stops by itself
Pump and/or trigger
gun is leaking
Contact your nearest service centre
No water supply
Connect inlet water.
Machine starts but no
water comes out
Water filter blocked
Clean the filter
Nozzle blocked
Clean the nozzle with a needle and by
spraying water backwards through the nozzle