Error code 

Explanation 

W08: Low water level  

Warning: The float switch detects, or has detected, air 

at the top of the boiler. The boiler stops the 

regulation and the circulation pump; if the air 

disappears, the regulation will be resumed. 

B03: Ext Limitation 

Limitation: External limitation: blockage  

or alternate temperature is activated. 

B04: Manual operation 

Limitation: Manual operation of the boiler is activated (switch  

off automatically after 4 minutes). 

B08: ECO active 

Limitation: The ECO function is activated. 

X01: Boot 

Limitation: Start-up has taken place. 

 

Alarm 
When the boiler activates an alarm, an alarm signal sounds and the red indicator light flashes. When the 

user or installation engineer has acknowledged the alarm, the alarm signal stops and the red indicator 

light stays on until the cause of the alarm ceases by itself or is rectified. Information about the alarm 

remains in the log list.  
Warning 
When the boiler activates a warning, the yellow indicator light flashes. When the user  

or installation engineer has acknowledged the warning, the yellow indicator light stays  

on until the cause of the warning ceases by itself or is rectified. Information about  

the warning remains in the log list.  
Limitation 
When a value in the boiler reaches a set limit value and the boiler activates a limitation, the green 

indicator light flashes. When no limitations are activated, the green indicator light will be permanently 

lit. 
 
3.5.

 

Technical specification 

MP4 G3 and MP6 G3 

Height 

700 mm 

Width 

420 mm 

Depth 

200 mm 

Protection class 

IP x1 

Volume 

1.4 litres 

Expansion tank volume pre-charge pressure  2 litres / 1.5 bar 
Design pressure 

2.5 bar 

Test pressure 

3.6 bar 

Safety valve 

2.5 bar 

Design temperature 

80°C 

Temperature range 

10  – 60°C 

Ambient temperature 

10  – 30°C 

Weight 

17 kg 

Installation height for immersion  

heater replacement 

At least 400 mm 

Manufactured to 

PED 2014/68/EU article 4.3 

Содержание MP4 G3

Страница 1: ...Mini Boiler MP4 G3 and MP6 G3 MANUAL Use and Installation...

Страница 2: ...1 2 4 6 Alarms warnings and limitations 12 2 5 Maintenance 13 2 6 Troubleshooting 16 3 Installation Manual 18 3 1 Safety 18 3 2 Installation 18 3 2 1 Installation overview 18 3 2 2 Preparations 18 3 2...

Страница 3: ...you will find technical information as well as instructions relating to installation and service NOTE Installation and service may only be carried out by a qualified installation engineer 1 3 Explanat...

Страница 4: ...ibed on pages 13 16 Always contact your installation engineer for service The boiler is not permitted to be modified changed or converted in any way Never place any combustible material on the boiler...

Страница 5: ...set to 1 5 bar YES to bar The water pressure must not be below the pre charge pressure 0 2 bar Example If the pre charge pressure has been adjusted to 1 6 bar the water pressure must be between 1 8 an...

Страница 6: ...Version MP4 6 G3 08 01 2024 5 2 3 Overview...

Страница 7: ...the boiler s electronics from being splashed with water 1 Control panel 2 Power switch 3 Overheating protection 4 Vent valve 5 Safety valve 6 Pressure gauge 7 Drain water tank 8 Expansion tank 9 Circ...

Страница 8: ...u you have selected Cover 15 The cover protects the boiler from contaminants The cover must always be mounted on the boiler except during maintenance and when changing settings Locking mechanism 16 Th...

Страница 9: ...r temperature exceeds 80 C If the overheating protection is triggered you will need to reset it manually Read more about resetting the overheating protection on page 12 2 4 Functions and settings Do n...

Страница 10: ...o the home screen Basic settings The installation engineer sets the language time and date at the time of installation In the event of a power cut lasting longer than 3 4 days you or the installation...

Страница 11: ...to the outdoor temperature The installation engineer sets a heating curve that is adapted to the heating surface s insulation and the design of the heating system If you have installed a room unit the...

Страница 12: ...start the boiler again rather contact your installation engineer for troubleshooting and remedial actions Over temperature protection The over temperature protection is a digital safety feature The b...

Страница 13: ...nd contact your installation engineer for troubleshooting and remedial actions Anti freeze If the boiler or system is in a low temperature environment the installation engineer can add anti freeze and...

Страница 14: ...ted Activity log The boiler saves operational information in an activity log The installation engineer can use this information for troubleshooting and to make adjustments 2 5 Maintenance In order for...

Страница 15: ...ystem does not lose too much water and pressure The water pressure should be checked when the boiler is cold For every quarter of a turn anticlockwise a popping sound can be heard 8 Open and close the...

Страница 16: ...ng valve is missing contact your installation engineer If you would like help adjusting the water pressure please contact your installation engineer Empty the drain water tank 12 Remove the drain wate...

Страница 17: ...s or the warning is repeated contact your installation engineer for troubleshooting and remedial actions Red indicator light flashes The boiler has activated an alarm and turned itself off Make a note...

Страница 18: ...protection or contact your installation engineer Read how to reset the overheating protection on page 12 Acknowledging an alarm warning or limitation 1 Press the button furthest to the left 2 Press th...

Страница 19: ...not included in the boiler delivery 2 Install the boiler 3 Install the pipe system 4 Fill with water 5 Install the electricity 6 Test the boiler in accordance with the Installation engineer s checkli...

Страница 20: ...oiler so that the immersion heater can be replaced if necessary Install the outdoor sensor Connect the outdoor sensor to the boiler using a cable with a cross section of at least 0 5 mm2 and a maximum...

Страница 21: ...ures Pipe system Shut off throttle valves Filling and drain valve Flow direction Water source 3 2 5 Fill with water and adjust the pressure Always check that the expansion tank has sufficient volume C...

Страница 22: ...has a capacity of 2 litres and the preset pre charge pressure is 1 5 bar It can handle a system volume of 70 litres at 60 C and 5 metres of static pressure Adjust the bypass valve To safeguard the fl...

Страница 23: ...ump 4 Overheating protection 5 Control switch 6 Cable between panel and power board 7 Boiler temperature sensor 8 Connection for outdoor temperature sensor 9 Connection external blocking alternative t...

Страница 24: ...ation to electrical installation may only be carried out by qualified personnel For an explanation of labels see page 22 Jumper N X option for single phase coupling and for increasing the power in the...

Страница 25: ...e protection 10 A Jumper N X Two phases without jumper MP4 2 25 kW 400 V 2N 5 6 A MP6 3 0 kW 400 V 2N 7 5 A Power cable 4 x 1 5 mm2 Fuse protection 2 x 10 A Two phases with jumper MP4 3 0 kW 400 V 2N...

Страница 26: ...to refit the red cap to ensure that the vent valve works automatically The float switch temporarily turns off the boiler and triggers a warning if the vent valve is unable to vent the boiler automatic...

Страница 27: ...Version MP4 6 G3 08 01 2024 26 Menu overview...

Страница 28: ...ation is activated you can test operate the circulation pump manually Select 1 to start the circulation pump and 0 to stop the circulation pump ECO function Main menu The ECO function must be switched...

Страница 29: ...ly deactivated after four minutes of inactivity Manual operation Installation engineer settings Advanced Manual operation is used to test the boiler s functions manually Max flow Installation engineer...

Страница 30: ...low buzzer Installation engineer settings Advanced Select ON to activate the alarm signal and select OFF to deactivate the alarm signal The factory setting is ON USB Installation engineer settings Adv...

Страница 31: ...tion information on page 4 of the User Manual Demonstrate the boiler to the customer in accordance with Customer demonstration handover on page 32 Fill out and post the installation registration to re...

Страница 32: ...uses and that the boiler s control switch is in the on position The group fuses for the boiler are triggered The immersion heater is broken Check by checking the insulation of the immersion heater Mea...

Страница 33: ...h boiler temp Warning The over temperature protection has temporarily stopped the boiler from heating When the boiler temperature has dropped by 5 C regulation will be resumed W03 Low boiler temp Warn...

Страница 34: ...f or is rectified Information about the alarm remains in the log list Warning When the boiler activates a warning the yellow indicator light flashes When the user or installation engineer has acknowle...

Страница 35: ...230 V 400 V 400 V 400 V Frequency 50 60 50 60 50 60 50 60 Current 6 5 A 5 6 A 7 5 A 6 5 A Fuse protectio 10 A 2 x 10 2 x 10 3 x 10 MP6 G3 Power options 2 0 kW 3 0 kW 4 0 kW 6 0 kW Voltage 230 V 400 V...

Страница 36: ...246221 Expansion tank 1 245117 H bypass bypass valve 1 280018 Insulation immersion heater container 1 210224 Cable power panel circuit board 1 210234 Power circuit board 1 720259 Cover 1 380051 Pressu...

Отзывы: