39 Micro switch for safety guard can be exchanged in the following way:
a)
Remove the lid of the mixer
(1)
and the operating panel
(7).
b)
Screw out the pointed screw
(37)
, and the cam disc
(38)
can be removed.
c)
The fitting with micro switch
(39)
can now be remo-
ved, and the micro can be exchanged by removing
the screws
(40)
. It might be necessary to loosen the
screws
(41)
before the fitting can be taken out.
d)
The new micro switch is to be screwed on to the
fitting, and the fitting to be placed in the machine. It
is important that the two screws
(41)
are adjusted
so that the fitting is horizontal.
35 Exchange the switch for bowl detection (with bracket) in the following way:
a)
Take off the lid of the mixer
(1)
and the plastic cover
(2).
b)
Remove the base for motor
(13)
with the motor
(17).
c)
The bracket with the bowl detector switch
(35)
can be taken out by loose-
ning the two bolts
(36)
and removing the two red wires. Location of the
jumper must not be changed.
d)
The new bracket with new switch is mounted in the mixer.
e)
The wires must be fitted on the switch so that the two middle legs are empty.