C
HAPTER
3. M
AINTENANCE
P
ROCEDURES
3-19
02.9628.0010
CONFIDENTIAL
7-Oct-97
Table 3-9 General Error Codes
Error
Number
Error for PSU Test (15)
MSC = F
NSC = Parameter
LDC = Error Number
Error for Mechanics
Tests (1 to 11)
MSC = Test Number
NSC + LSC = Error
Number
Results Associated With
Mechanics Error Codes
(After Error Code)
01
IPRES
No data activity error
02
PSOT
Data activity error
03
HOT
No reset error
04
SHORT
Count does not change
Display count last seen
05
NOT IPRES
Bit count is not sequential
Display received and
expected count
11
Sensor hit too early,
motion impeded
12
Backlash too small (0)
13
Backlash too large.
Indicate backlash value
(half steps in
hexadecimal)
14
Sensor not hit, motion
impeded, sensor
permanently high
15
Sensor permanently low