background image

FRG-700 Inverted Magnetron Pirani Gauge

 

 

 

 

25

 

 

8  Returning the Product 

WARNING

WARNING: forwarding contaminated products 
Contaminated products (e.g. radioactive, toxic, caustic or biological 
hazard) can be detrimental to health and environment. 
Products returned to VARIAN should preferably be free of harmful 
substances. Adhere to the forwarding regulations of all involved coun-
tries and forwarding companies and enclose a duly completed decla-
ration of contamination. 

 

 

 

Products that are not clearly declared as "free of harmful substances" are decon-
taminated at the expense of the customer. 
Products not accompanied by a duly completed declaration of contamination are 
returned to the sender at his own expense. 
 
 
 
 
 
 
 
 

 

9 Disposal 

DANGER

DANGER: contaminated parts 
Contaminated parts can be detrimental to health and environment. 
Before beginning to work, find out whether any parts are contami-
nated. Adhere to the relevant regulations and take the necessary pre-
cautions when handling contaminated parts. 

 

 

 

N

WARNING

WARNING: substances detrimental to the environment 
Products or parts thereof (mechanical and electric components, opera-
ting fluids etc.) can be detrimental to the environment. 
Dispose of such substances in accordance with the relevant local re-
gulations. 

 

 

 

 

After disassembling the product, separate its components according to the 
following criteria: 
 

 

Contaminated components (radioactive, toxic, caustic or biological hazard etc.) 
must be decontaminated in accordance with the relevant national regulations, 
separated according to their materials, and disposed of. 
 

 

Such components must be separated according to their materials and recycled. 
 
 
 

Separating the components 

Contaminated components 

Other components 

Содержание FRG-700 series

Страница 1: ...vacuum technologies FRG 700 Inverted Magnetron Pirani Gauge INSTRUCTION MANUAL Manual No tqna48e1 Revision November 2008...

Страница 2: ...2 FRG 700 Inverted Magnetron Pirani Gauge Copyright 2008 Vacuum Technologies...

Страница 3: ...epresentatives of Seller which are inconsistent or in conflict with the terms of this warranty shall not be bin ding upon Seller unless reduced to writing and approved by an officer of Seller Warranty...

Страница 4: ...the right to make technical changes without prior notice All dimensions in mm The Inverted Magnetron Pirani Gauge FRG 700 has been designed for vacuum measurement in the pressure range of 5 10 9 1000...

Страница 5: ...ges With CF Flanges 12 3 2 Electrical Connection 13 3 2 1 Use With an VARIAN Controller 13 3 2 2 Use With Another Control Device 13 4 Operation 14 4 1 Measurement Principle Measuring Behavior 14 5 Dei...

Страница 6: ...ocess media Consider possible reactions e g explosion of the process media due to the heat generated by the product Adhere to the applicable regulations and take the necessary precautions for all work...

Страница 7: ...85 k referenced to supply common Status Pin 6 p 10 2 mbar Pirani only mode Low 0 V p 10 2 mbar Cold cathode not ignited Pirani only mode Low 0 V p 10 2 mbar Cold cathode ignited Combined Pirani cold c...

Страница 8: ...curacy 10 V Supply common signal common conducted separately Materials exposed to vacuum Vacuum connection Measuring chamber Feedthrough Internal seals Anode Ignition aid Pirani measuring tube Pirani...

Страница 9: ...FRG 700 Inverted Magnetron Pirani Gauge 9 Dimensions mm 18 DN 25 ISO KF DN 40 CF F 24 92 63 5 28 55 60 75 Weight FRG700KF25 FRG700CF35 700 g 980 g...

Страница 10: ...n the event of a fault The gauge must be electrically connected to the grounded vacuum chamber The connection must conform to the requirements of protective connection according to EN 61010 CF connect...

Страница 11: ...stment should be possible after the gauge has been installed be sure to install it so that the HV and ATM trimmer potentiometers can be accessed with a screw driver 17 When making a CF flange connecti...

Страница 12: ...difficult to separate the magnet unit and the measuring chamber 7 d Make the flange connection between the gauge and the vacuum system e Remount the magnet unit and lock it with the hexagon head scre...

Страница 13: ...m 8 poles FCC 68 1 8 Electrical connection Pin 1 Supply 15 30 VDC Pin 2 Supply common Pin 3 Signal output measuring signal Pin 4 Identification Pin 5 Signal common Pin 6 Status Pin 7 8 n c 10 10 Ident...

Страница 14: ...d only at pressures 1 10 2 mbar The identification output pin 6 indicates the current status of the gauge Pressure Lamp on the gauge Operating mode Pin 6 p 1 10 2 mbar Pirani only mode Low 0 V p 1 10...

Страница 15: ...tion as well as reduced up time and maintenance cycles With constantly low pressures p 1 10 6 mbar the gauge can be operated for more than one year without cleaning cleaning the gauge 19 Contamination...

Страница 16: ...acuum component When handling vacuum components take appropriate measures to ensure cleanliness and prevent damages Caution Caution dirt sensitive area Touching the product or parts thereof with bare...

Страница 17: ...s when working in this area The gauge is factory calibrated If used under different climatic conditions through extreme temperatures aging or contamination and after exchanging the sensor the characte...

Страница 18: ...rn the potentiometer counter clockwise by 1 3 of a turn s Vent the gauge with air or nitrogen to atmospheric pressure and wait at least 10 minutes t Turn the nameplate clockwise until the mechanical s...

Страница 19: ...ench AF 1 5 Allen wrench AF 3 Open end wrench 7 0 mm Pliers for circlip Polishing cloth 400 grain or Scotch Brite Tweezers Cleaning alcohol Mounting tool for ignition aid Ignition aid Pirani element 1...

Страница 20: ...g cloth rub the inside walls of the measuring chamber and the polarity insert to a bright finish The sealing surfaces must only be worked concentrically o Rinse the measuring chamber and the polarity...

Страница 21: ...l ignition aid 10a into the measuring chamber p Insert the Pirani element 13 with the FPM seal 13a slid over it into the corresponding bore hole q Carefully place the pressure piece 9 on the measuring...

Страница 22: ...fore performing any tightness tests put the product out of operation and remove the electronics unit w Mount the magnet unit 4 and lock it with the screw 3 Carefully mount the electronics unit 2 Make...

Страница 23: ...ignited Wait until the gas dis charge ignites in case of contamination with insu lation layers the cold cathode may completely fail to ignite Cleaning 19 The FRG has only been activated with p 3 10 9...

Страница 24: ...ng to the spare parts list Pos Description Ordering number 12 13a 11 10a Maintenance kit consisting of 1 support ring 1 O ring FPM 3 69 1 78 1 O ring FPM 10 82 1 78 3 ignition aid FRG700MAINT 13 12 13...

Страница 25: ...s Contaminated parts can be detrimental to health and environment Before beginning to work find out whether any parts are contami nated Adhere to the relevant regulations and take the necessary pre ca...

Страница 26: ...overrange Pa mbar torr Measuring signal U V Pressure p Meas signal U V Pressure p mbar Pressure p Torr Pressure p Pa 0 5 Sensor error 0 5 1 82 Underrange 1 82 2 0 2 6 3 2 3 8 4 4 5 0 5 6 6 2 6 8 7 4...

Страница 27: ...8 2 4 6 8 Water vapor peff mbar Indication range above 10 2 mbar Xe Kr Ar CO2 Freon 12 Pressure indicated gauge calibrated for air 6 4 2 6 4 2 6 4 2 10 4 8 6 4 2 10 6 2 4 6 10 5 10 4 Ar 10 5 8 6 4 2...

Страница 28: ...conversion formula peff K pressure indicated where gas type K air O2 CO N2 1 0 Xe 0 4 Kr 0 5 Ar 0 8 H2 2 4 Ne 4 1 He 5 9 These conversion factors are average values A mixture of gases and vapors is o...