background image

Varian, Inc. 

Varian, Inc. 

CP-4900 Firmware Installation Manual  

Page: 13 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

25. When the Micro-GC is ready, click “Get MPU Version” : the current firmware must be 

upgraded to version 2.12. 

 
 

26. The instrument is now upgraded to V2.12, if the instrument is a CP4900 PRO,  you 

need to upgrade the PROstation software. (CP-4900 PRO software tools partnumber  
CP741409). 

 
 

Содержание CP-4900 Micro-GC

Страница 1: ...ands CP501459 Rev 4 July 2009 CP 4900 Micro GC Firmware Update Manual The procedures outlined in this document are to be implemented by trained Varian Service personnel only and are not intended for C...

Страница 2: ...Installation Manual Page 2 Installation of the Micro GC Firmware Update Tool 1 When selecting the Firmware update tool it will install the MPU Firmware setup and the VirtualBox Software to perform an...

Страница 3: ...3 Please read the license agreement carefully if agreed select I agree to the terms of this License agreement then click next to continue with the next step 4 Default the program will be installed in...

Страница 4: ...Varian Inc Varian Inc CP 4900 Firmware Installation Manual Page 4 5 Shortcut will be created click next 6 Click Next to start installation...

Страница 5: ...Varian Inc CP 4900 Firmware Installation Manual Page 5 7 Click Finish to complete the installation 8 After installation of the MPU Setup it will install the VirtualBox this can take several minutes 9...

Страница 6: ...Firmware Installation Manual Page 6 10 Please read the license agreement carefully if agreed select I agree to the terms of this License agreement then click next to continue with the next step 11 No...

Страница 7: ...Varian Inc Varian Inc CP 4900 Firmware Installation Manual Page 7 12 Select the way you want features to be installed 13 Proceed with installation now click YES...

Страница 8: ...stallation Manual Page 8 14 Click install to start installation 15 Depending on the Windows settings it is possible that the above message will popup several times that the Virtual software is not pas...

Страница 9: ...Varian Inc Varian Inc CP 4900 Firmware Installation Manual Page 9 16 Uncheck the Start Sun xVM VitualBox after installation click Finish 17 Click yes to start the Update...

Страница 10: ...900 Firmware Installation Manual Page 10 18 Enter the IP address of the CP 4900 Micro GC and select Get MPU version this Update can only be done with V1 40 or higher Click Update Firmware and the upda...

Страница 11: ...oard eg when your keyboard is French then type in fr followed by enter if the Keyboard is default US keyboard then hit Enter 21 When the prompt root sysresccd root appears then type in the following c...

Страница 12: ...Inc Varian Inc CP 4900 Firmware Installation Manual Page 12 22 Press Ctrl C to finalize the Update wait until the Micro GC is ready 23 Press in the right corner X 24 Select Power off the machine and c...

Страница 13: ...When the Micro GC is ready click Get MPU Version the current firmware must be upgraded to version 2 12 26 The instrument is now upgraded to V2 12 if the instrument is a CP4900 PRO you need to upgrade...