Varian 969-9860 Скачать руководство пользователя страница 10

TECHNICAL INFORMATION

5

87-900-847-01 (B)

HAND-HELD TERMINAL DESCRIPTION

The Hand-held terminal is on LCD alphanumeric
display and keyboard, which provides useful real time
indications of the operating conditions/parameters of
the Turbo-V 60 pump series when connected to a
Turbo-V 60 controller without front panel.

Moreover, it is possible to reprogram the controller
parameters or troubleshooting pump/controller.

The Hand-held terminal, 188 mm height x 110 mm wide
x 41 mm deep (7.4" x 4.3" x 1.6"), is connected and
powered to the Turbo-V controller via a 1.5 meters (5 ft)
cable.

USE

General

Make all vacuum manifold and electrical connections and
refer to Turbo-V pump instruction manual before to
operating the Turbo-V controller.

!

To avoid injury to personnel and damage to the
equipment, if the pump is laying on a table make sure it
is steady. Never operate the Turbo-V pump if the pump
inlet is not connected to the system or blanked off.

Connect the hand-held terminal to the Turbo-V controller.
Plug the controller power cable into a suitable power
source.
If the hand-held terminal is used to monitor the pump
operating conditions, follow paragraph "Monitor Mode";
if reprogramming or trouble shooting is required, follow
paragraph "Program Mode"; and the following
paragraph.

Monitor Mode

By pressing the CURRENT push-button, the display
shows:

I

=

0

.

0

0 A

P

=

0 W

X

.

.

K R P M

X X

°

C

where:

 

I

 = is the DC current drawn by the pump range

(0.00 to 9.99 Ampere)

 

P

 = is the DC power drawn by the pump (range 0 to

999 Watt)

 

KRPM

  = is the theoretical rotational speed of the

pump as a function of the controller output
frequency (range 17 to 99 KRPM)

 

°C 

= is the temperature of the outer ring of the

upper bearing (range 00 to 99 °C)

 

= during operation a selected set point condition

(1 or 2 contrast inverted) appears when the
programmed threshold speed value is not reached.

 

  Press the CYCLE NUMBER once and the display

shows:

X X X X C Y C L

E

X X X X X m

P U M P

L

I

F

E

X X X X X h

where:

 

CYCLE 

= are the cycles performed (range 0 to 9999)

 

m

 = is the elapsed time related to the cycle number

displayed (range 0 to 99999 minutes)

 

PUMP LIFE

 = is the total operation time of the pump

(range 0 to 99999 hours).

Program Mode

Refer to paragraph "Speed Adjustment" to program/
adjust the high and low speed values. This feature is
only applicable when a dedicated software is installed
on the Turbo-V 60 controller microprocessor (e.g. for
leak detector operation).

FRONT / REMOTE/ 232 Selection

  Press CYCLE NUMBER and PUMP CURRENT

push-buttons together for at least 2 seconds and
the processor enters in a routine where it is
possible to program the controller.
In this routine, the CYCLE push-button is used for
choosing/changing the value or condition; the
PUMP CURRENT push-button is used to enter and
confirm the value. At any time it is possible to exit
this routine by pressing the CYCLE and PUMP
CURRENT push-buttons at the same time for at
least 2 seconds.

The display shows:

F R O N T

/

R E M O T E

/

2

3

2

S E L E C T

I

O N

:

X X X X X X

where: 

XXXXXX

 = means the word FRONT or

REMOTE, or RS 232 depending on the last
selection.

Select the FRONT panel operation if the front panel
command is used.

After choosing the desired selection by pressing the
CYCLE push-button, press the PUMP CURRENT
push-button to enter the value.

WARNING!

Содержание 969-9860

Страница 1: ...87 900 847 01 B APRIL 2002 MANUALE DI ISTRUZIONI BEDIENUNGSHANDBUCH NOTICE DE MODE D EMPLOI INSTRUCTION MANUAL Hand held Terminal Model 969 9860 vacuum technologies ...

Страница 2: ...Hand held Terminal ...

Страница 3: ......

Страница 4: ......

Страница 5: ...SCRIPTION 5 USE 5 General 5 Monitor Mode 5 Program Mode 5 FRONT REMOTE 232 Selection 5 Monitor Relay Programming 6 Reset Command 7 Starting the Pump 8 Operating the Pump 8 Low Speed Operation 8 Speed Adjustment 9 Pump Shutdown 10 Power Failure 10 Remote Control Mode Operation 10 RS 232 Control Mode Operation 10 ERROR MESSAGES 11 ...

Страница 6: ...le Durante l operazione di disimballaggio prestare particolare attenzione a non lasciar cadere l Hand Held Terminal e a non sottoporlo ad urti Non disperdere l imballo nell ambiente Il materiale è completamente riciclabile e risponde alla direttiva CEE 85 399 per la tutela dell ambiente Comandi indicatori e connettori dell Hand Held Terminal Di seguito sono illustrati il pannello dell Hand Held Te...

Страница 7: ...ändigen örtlichen Verkaufsstelle gemeldet werden Beim Auspacken vorsichtig vorgehen damit dem Gerät nicht herunter fällt oder Stößen ausgesetzt wird Das Verpackungsmaterial muß korrekt entsorgt werden Es ist vollständig recyclebar und entspricht der EG Richtlinie 85 399 für Umweltschutz Steuerungen Anzeigen und Anschlüsse des Handterminals Nachstehend werden die Steuertafel des Handterminals Für w...

Страница 8: ... particulièrement à ne pas laisser tomber le contrôleur et à ne lui faire subir aucun choc Ne pas jeter l emballage dans la nature Le matériel est entièrement recyclable et il est conforme aux directives CEE 83 399 en matière de protection de l environnement Commandes indicateurs et connecteurs du hand held terminal On présente ci dessous le tableau de commande du hand held terminal Pour de plus a...

Страница 9: ...ffice When unpacking the Hand held terminal ensure that it is not dropped or subjected to any form of impact Do not dispose of the packing materials in an unauthorized manner The material is 100 recyclable and complies with EEC Directive 85 399 Hand held Terminal Controls Indicators and Connectors The following paragraph illustrates the Hand held terminal panel More details are contained in the ap...

Страница 10: ...speed of the pump as a function of the controller output frequency range 17 to 99 KRPM C is the temperature of the outer ring of the upper bearing range 00 to 99 C X during operation a selected set point condition 1 or 2 contrast inverted appears when the programmed threshold speed value is not reached Press the CYCLE NUMBER once and the display shows X X X X C Y C L E X X X X X m P U M P L I F E ...

Страница 11: ...following figure Monitor Relay Programming The display shows S P E E D T H R E S H O L D S E L E C T I O N X X K R P M where XXKRPM is the switch point of relay R1 at the preset turbopump speed adjustable from 00 to 99 KRPM The speed threshold will condition the R1 and R2 operation see the following cycle diagram Select the first number by pressing the CYCLE NUMBER push button then enter the value...

Страница 12: ... I F E X X X X X h R E S E T X X X where PUMP LIFE is the elapsed operating time range 000 to 99999 hours RESET XXX YES or NO If YES is selected the pump life shall be reset to 000 After selecting YES press the PUMP CURRENT push button to enter the command and the display shows as follows I 0 0 0 A P 0 W X K R P M X X C NOTE When PUMP LIFE is reset to 000 the CYCLE number is also reset to 000 ...

Страница 13: ...en the pump reaches the normal speed the display reverts to the previous figure Operating the Pump After the starting period if the system has a vacuum leak or the pressure in the pump chamber is high from 1 mbar to atmosphere the pump continues to operate indefinitely If the gas load at the turbopump inlet flange continues to stay high the power drawn by the turbopump increases up to the maximum ...

Страница 14: ...essing CYCLE NUMBER and PUMP CURRENT pushbuttons together for at least 4 seconds the processor enters in a routine where it is possible to adjust the rotational speed The display shows H I G H S P E E D S E L E C T X X X X X R P M where XXXXX is the pump rotational HIGH SPEED value selected In this routing the CYCLE pushbutton is used to increase the speed value and the LOW SPEED pushbutton is use...

Страница 15: ...tarts the interconnected devices and the turbopump in the proper sequence The display shows P U M P I S S T A R T I N G 1 2 X X K R P M until normal operation achieved Remote Control Mode Operation If remote signals are used to operate the controller it must be programmed for remote operation see paragraph Program Mode and when ready to start the display shows as in the following figure P U M P R ...

Страница 16: ... pump NOTE If the controller transformer temperature exceeds 90 C the pump is shut off and the display will be as shown in the following figure F A U L T C O N T R O L L E R O V E R T E M P E R A T U R E The message will stay on until the temperature decreases below threshold value Press the STOP RESET pushbutton twice to start the pump NOTE If in normal condition the current drawn by the pump is ...

Страница 17: ...NTIFICATION Product Description Varian P N Varian S N Purchase Reference TYPE OF RETURN check appropriate box Paid Exchange Paid Repair Warranty Exchange Warranty Repair Loaner Return Credit Shipping Error Evaluation Return Calibration Other HEALTH and SAFETY CERTIFICATION Varian Vacuum Technologies CAN NOT ACCEPT any equipment which contains BIOLOGICAL HAZARDS or RADIOACTIVITY Call Varian Custome...

Страница 18: ...ate No zero high backround Gauge tube not working Display problem Vacuum system unstable Cannot reach test mode Communication failure Degas not working Failed to start Other Error code on display Other Customer application Customer application PRIMARY PUMPS DIFFUSION PUMPS Pump doesn t start Noisy pump describe Heater failure Electrical problem Doesn t reach vacuum Over temperature Doesn t reach v...

Страница 19: ...ian India PVT LTD 101 108 1st Floor 1010 Competent House 7 Nangal Raya Business Centre New Delhi 110 046 India Tel 91 11 5548444 Fax 91 11 5548445 Italy Varian Vacuum Technologies Via F lli Varian 54 10040 Leini Torino Italy Tel 39 011 997 9111 Fax 39 011 997 9350 Japan Varian Vacuum Technologies Sumitomo Shibaura Building 8th Floor 4 16 36 Shibaura Minato ku Tokyo 108 Japan Tel 81 3 5232 1253 Fax...

Отзывы: