8
SPECIFICATIONS
Model
65710
65715
Trade Name
VARI 11 TON SUPER
FORCE
VARI 14 TON SUPER
FORCE
Motor (S6 40 %)*
400 V 3~ 50 Hz
3300 W 5,3 A
400 V 3~ 50 Hz
3500 W 7,1 A
Log Size
Capacity
Diameter
10-30 cm
Length
56-104 cm
Maximum Force
11 t ± 10 %
14 t ± 10 %
Hydraulic Pressure
25,5 MPa
24,6 MPa
Hydraulic Oil Capacity
7,0 l
7,5 l
Ram Travel
85 cm
Speed
Forward
23,2 cm/s
21,8 cm/s
4,9 cm/s
4,2 cm/s
Retract
6,1 cm/s
5,2 cm/s
Noise Pressure Level (LpA)
≤
80 dB (A)
Vibration
2,5 m/s
2
Overall
Sizes
Length
144 cm
144 cm
Width
133 cm
135 cm
Height
228 cm
228 cm
Weight
172,5 kg
184,9 kg
* S6 40%, continuous operation periodic duty: time of one load cycle is 10 minutes,
operation time at constant load is 4 minutes, operation time at no-load is 6 minutes.
APPLICATION CONDITIONS
This log splitter is designed for operating under ambient temperatures b5°C
and +40°C and for installation at altitudes not more than 1000 m above M.S.L. The
surrounding humidity should be less than 50 % at 40°C. It can be stored or
transported under ambient temperatures between –25°C and +55°C.
ELECTRICAL REQUIREMENTS
With 3 phase 400 Volt / 50 Hz motor, the log splitter should be connected to standard
400 V ± 10 % / 50 Hz ± 1 Hz electrical supply which has protection devices of under-
voltage, over-voltage, over-current as well as a residual current device (RCD) with
maximum residual current rated at 0,03 A.
The mains connection and extension cable must have 5 wires = 3P + N + PE
(3/N/PE). The mains connection must have maximum 16 A fuse. Electrical
connection rubber cables must comply with IEC 60245, which is always marked with
symbol H 07 RN. Cables should be identified, as it is a legal requirement. The cable
is not supplied with the machine.
Содержание 65710
Страница 21: ...21 PART LIST...