Vari 401511 Скачать руководство пользователя страница 12

CODE

DESCRIPTION

TROUBLESHOOTING SOLUTION

E01

Over Current

Protection

Over current protection feature triggered, over current always 

caused by over loading. Remove items or reduce weight from con-

centrated area (rated loading is average distribution). Follow the 

reset instruction to reset the system. If error persists, contact Vari.

E07

Hall Error

E07 will display if the cable connected to the M1 port is not fully 

secured. Disconnect and reconnect the cable. Follow below in-

structions to reset (RST) the desk. If the error persists, contact Vari.

H01

Over Duty

Protection

If the desk is raised and lowered continously for more than 2 

minutes, it will display this code and cease working temporarily to 

protect the mechanism from overheating. Stop adjusting the desk, 

and resume after 20 minutes.

RST

System Reset

If the display is showing an ERROR CODE: 

Make sure all cables 

are securely connected. Press and hold the down button (about 

5 seconds) on the control panel until RST flashes on the screen. 

Release the down button, and continue with the steps below. 

If the display is already flashing “RST”:

 Press and hold the down 

button until the desk reaches the lowest height, raise slightly, and 

finally displaying height number. Do not release the down button 

until height number is shown on the control panel. The desk is now 

ready to use. 

(800) 207-2587

Содержание 401511

Страница 1: ...Essential Electric Standing Desk 48x24 Patent and trademark information vari com patents 2021 Varidesk LLC All rights reserved Solid Top 2 People Required for Assembly Holds up to 150 lb 68 kg...

Страница 2: ...1 DESKTOP x1 FOOT x2 TRANSMISSION SHAFT x1 TRANSMISSION SHAFT COVER x1 CONTROL PANEL x1 CONTROL BOX x1 M6 ALLEN KEY x1 M10 ALLEN KEY x1 M6 14 BOLT x4 M6 WASHER x4 HEX WRENCH x1 PUSH IN RIVET PINS x6 M...

Страница 3: ...move the desktop from the box and set it on top of the box with the frame facing up Locate the four slots on either side of the desk frame Next using the locator pins on the base of each leg slide the...

Страница 4: ...aft of the leg with the motor moving it all the way to the end until the shaft is level with the desktop Then slide the transmission shaft to the left until it is on both legs hex shafts NOTE You migh...

Страница 5: ...ntrol panel bracket on the front edge of the desk see the diagram on Step 2 Slide the control panel into the bracket 5 Using four 4 M10 25 bolts turn the M10 Allen key clockwise to secure both feet to...

Страница 6: ...abeled HS Next connect the cord attached to the motor into the slot on the control box labeled M1 Lastly plug the power cord into the slot on the control box labeled AC 7 Locate the control box bracke...

Страница 7: ...9 Using two people lift and flip the desk over along the back edge and set it down gently on its feet Connect to a power source The desk is now ready to use 5...

Страница 8: ...the desk lowers a little bit more slightly rises and stops Release the button The new program is saved and your desk is now ready to use Initial Setup To toggle from inches to centimeters on the displ...

Страница 9: ...t is now set To Remove Upper Lower Limit Positions Press the M button and release The LED display will read S Within 5 seconds press and hold the M button again for 2 seconds The LED display will chan...

Страница 10: ...rocess by pressing and holding the DOWN button again until the desk lowers a little bit more slightly rises and stops Release the button The new starting height value is saved and your desk is now rea...

Страница 11: ...ARNING Do not open any components there is a danger of electric shock WARNING Keep plug away from heated surfaces CAUTION Beverages such as water or coffee could cause product failure if spilled WARNI...

Страница 12: ...f the desk is raised and lowered continously for more than 2 minutes it will display this code and cease working temporarily to protect the mechanism from overheating Stop adjusting the desk and resum...

Отзывы: