Troubleshooting Guide
If a problem is suspected, first try recalibrating the luminaire to prompt an error message.
Table A-2
below provides possible causes and remedies for various error messages and/or symptoms.
CAUTION:
Some troubleshooting is included for reference only. Performing remedies marked by
gray areas will void product warranty. Refer to the Vari-Lite Limited Warranty card included with the
product.
Note:
*The nature of the CDM lamp used in the VL1100CD ERS Luminaire prevents it from
restriking when it is hot after use. It takes approximately 15 minutes for the lamp to cool enough to
restrike.
Table A-2: Troubleshooting Guide
Error Display
Description
Possible Cause and Remedy
Pan/No Sens
Pan Sensor Not Found
EOT flag attached to large pulley is not engaging
the EOT sensor
- Ensure flag is attached to the large pulley
- Ensure that flag passes through the sensor at a
depth sufficient to engage the sensor beam
Pan belt disconnected, extremely loose or not
installed properly
- Properly install belt between pan motor and
large pulley
Pan/Encoder/Fail
Pan Encoder Failure
Main board pan/tilt connector (J9) disconnected
- Connect main board pan/tilt connector (J9)
Pan motor disconnected
- Connect pan motor power
Encoder faulty
- Replace pan end-of-travel/encoder sensor
assembly
TILT
NO
SENS
Tilt Sensor Not Found
EOT flag attached to large pulley is not engaging
the EOT sensor
- Ensure flag is attached to the large pulley
- Ensure that flag passes through the sensor at a
depth sufficient to engage the sensor beam
Tilt belt disconnected, extremely loose or not
installed properly
- Properly install belt between tilt motor and large
pulley
Tilt/Encoder/Fail
Tilt Encoder Failure
Main board pan/tilt connector (J9) disconnected
- Connect main board pan/tilt connector (J9)
Tilt motor disconnected
- Connect tilt motor power
Encoder faulty
- Replace pan end-of-travel/encoder sensor
assembly
Lamp/Strike/Fail
Lamp Strike Failure*
Lamp failed to strike after repeated attempts
- Replace lamp
Содержание VL1100CD
Страница 1: ......
Страница 13: ...FOREWORD 02 9665 0001 0 15 February 2011 xi ...
Страница 14: ...VARI LITE VL1100CD ERS LUMINAIRE USER S MANUAL xii 15 February 2011 02 9665 0001 0 ...
Страница 24: ...VARI LITE VL1100CD ERS LUMINAIRE USER S MANUAL 8 15 February 2011 02 9665 0001 0 Notes ...
Страница 60: ...VARI LITE VL1100CD ERS LUMINAIRE USER S MANUAL 44 15 February 2011 02 9665 0001 0 Notes ...
Страница 82: ...VARI LITE VL1100CD ERS LUMINAIRE USER S MANUAL 66 15 February 2011 02 9665 0001 0 Notes ...
Страница 83: ......