Operation and Description of Instrument Function
Average Temperature/Water Bottom Sensor and Converter
44
Installation and Operations Manual
VH92 Error Dis. Sel.
Item type: select
Default: 0_OFF
Selection: 0_OFF, 1_ON
Type of VH88 "Short Error Value" and VH89 "Open Error Value" display selection.
0_OFF: These 2 error messages will not be transmitted to the connected host gauge.
This function automatically excludes defect element in average temperature calculation.
1_ON: Error message will be transmitted to the host gauge. As a result, VH88 and 89"s
numeric error code will be displayed on host gauge default screen and may transmit to
upper receiver as well.
VH94 Polling Address
Item type: read and write
Default: 2
Range: 1 ~ 15
Polling address for HART communication
VH95 Manufacture ID
Item type: read only
Default: 17
The manufacturer ID for Hauser instrumentation.
VH96 Software Version:
Item type: read only
A display of installed software version.
VH97 Hardware Version
Item type: read only
A display of installed hardware version.
VH98 Below Bottom
Item type: select
Default: 0_OFF
Selection: 0_OFF, 1_ON
A type of error display when liquid level drops below #1 element (Bottom Point). Error
code "29" is displayed on VH80 and VH91 when 0_ON is selected.
VH99 Device Type Code
Item type: read only
Device type will be displayed.
190: Temperature measurement function only.
Содержание 4532
Страница 2: ......
Страница 6: ...Average Temperature Water Bottom Sensor and Converter 4 Installation and Operations Manual ...
Страница 10: ...Contents Average Temperature Water Bottom Sensor and Converter 4 Installation and Operations Manual ...
Страница 16: ...Safety instructions Average Temperature Water Bottom Sensor and Converter 6 Installation and Operations Manual ...
Страница 22: ...Installation Average Temperature Water Bottom Sensor and Converter 12 Installation and Operations Manual ...
Страница 32: ...Mounting Average Temperature Water Bottom Sensor and Converter 22 Installation and Operations Manual ...
Страница 36: ...Wiring Average Temperature Water Bottom Sensor and Converter 26 Installation and Operations Manual ...
Страница 40: ...Operating Average Temperature Water Bottom Sensor and Converter 30 Installation and Operations Manual ...
Страница 62: ...Technical data Average Temperature Water Bottom Sensor and Converter 52 Installation and Operations Manual ...
Страница 64: ...Order Structure Average Temperature Water Bottom Sensor and Converter 54 Installation and Operations Manual ...
Страница 68: ...Index Average Temperature Water Bottom Sensor and Converter 58 Installation and Operations Manual ...
Страница 69: ...Varec Inc 59 4532 NOTES ...