Страница 1: ...1 Installation and User guide Revision 2 Varde Oslo...

Страница 2: ...egulations and approval Page 4 Flooring and distance Page 5 Chimney Page 6 Air supply Page 7 Operation Page 8 How to light and stoke a fire Page 9 List of accessories Page 10 Vermiculite Page 11 How t...

Страница 3: ...Nominal Output 4 kW Heated area 30 105m2 Efficiency 78 Flue gas data 4 4g sek 245 C ved 20 C 11 pa Combustion chamber H x W x D 264 x 410 x 256mm Flue outlet 12 5 cm Mounting hight top 493cm Distance...

Страница 4: ...ction The stove is designed for intermittent combusti on and can be connected to a chimney used by other fireplaces as long as the appropriate rules and regulations are adhered to See the Building Reg...

Страница 5: ...ust be accessible Optimal combustion can only be obtained if fresh air is constantly admitted It is important therefore to ensure that this is the case The best way to provide a steady flow of fresh a...

Страница 6: ...at a room temperature of 20 C Varde stoves are always fitted with a smoke plate which redirects smoke to make its way to the chimney as effectively as possible This ensures that the heat from the smok...

Страница 7: ...ean and the remaining amount of ashes will be minimal Overheating Occors if too much wood is placed in the stove or if the combustion receives too much air Combustion Air Throttel Turn the Throttel to...

Страница 8: ...The Air amount can be regulated Handle towards left 3 Maximum Air Inlet Handle towards right 4 Minimum Air Inlet 2 1 3 4 Combustion Air 2 Push the Air Throttel 2 towards left 3 Your Stove is now in ig...

Страница 9: ...re in the combustion chamber before opening the door completely Place 2 logs in a cross on top of the embers approx 1 2 kg and close the door again To make sure the wood ignites quickly we recommend b...

Страница 10: ...e page 5 Use of fireguard When using the stove in situations where children and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should...

Страница 11: ...is a very porous material and should be handled with care When refilling the stove stoke the wood carefully and use a glove Only use original parts from Varde Ovne A S How too replace the Vermiculite...

Страница 12: ...the burning of wood Only dry wood with a moisture content of maximum 21 percent and the size to fit into the combustion chamber should be used The burning of moist wood will result in an increased am...

Страница 13: ...the dealer where you bought your stove or your chimney sweeper It is especially important to check the stove and the chimney for blockages after a long period of non use The enamelled surface of the s...

Страница 14: ...late and make sure there is free pas sage for the smoke The amount of combustion secondary air is insufficient Combustion is too intense Rope seals in the door or the ash pan are no longer tight and n...

Страница 15: ...rts at any time should be needed please chech the list below Vermiculit Set Item no XXXX Sealings Item no 1101 Glass Item no 1130503 Handle Item no 11306124 Cast iron Door Item no 1130526 Glass spring...

Страница 16: ...act with combustible material and the refore has no minimum thich ness requirement Note The dimensions are the mini mum dimensions unless otherwise stated Note The minimum distance from bottom of stov...

Страница 17: ...17 Test certificat Smoke Control DEFRA in England NS 3058 3059...

Страница 18: ...18 Test certificat from Teknologisk Institut is scanned and placed here...

Страница 19: ...on missing or wrong maintenance etc see instructions earlier Damages caused by external influence of a physical character Cost of transportation in connection with warranty repairs Assembling reassemb...

Страница 20: ...20 Kongevej 246 6510 Gram Danmark Tel 45 7482 0003 vardeovne dk...