BE CAREFUL : if a torque is applied to the wrench during power-on period, an initial torque offset will be
recorded in the memory. Displayed value won
’t be the actual applied torque.
Setup
1. Unit selection : press
U/S
. Unit selection is in cyclic : N.m, in.lb, ft.lb, kg.cm
2. Set target torque : press
up
or
down
buttons to increase or decrease torque value.
Peak / Track mode selection
1. Long press on
U/S
. Torque wrench displays
“modE”.
2. Press up or down buttons to select
P
(Peak) or
T
(Track).
3. To confirm your choice, press 2 times
U/S
.
Track mode operation
1. Start (press
C
) and set target torque.
2. Apply torque. In Track mode, torque wrench displays current applied torque.
3. When you reach 90% of target torque :
-
Buzzer : bip, bip, bip
…
-
Green LED :
“
●
”
4. When you reach 99.5% of target torque :
-
Buzzer : biiiiiiiiiiiiiiiiiiiiiiiiiip
-
Red LED :
“
●
”
Peak mode operation
1. Start (press
C
) and set target torque.
2. Apply torque. In Peak mode, torque wrench displays always the maximum applied torque.
3. When you reach 90% of target torque :
-
Buzzer : bip, bip, bip
…
-
Green LED :
“
●
”
4. When you reach 99.5% of target torque :
-
Buzzer : biiiiiiiiiiiiiiiiiiiiiiiiiip
-
Red LED :
“
●
”
5. The maximum value you have reached is flashing on display.
6. Press
C
to clear display and tighten another component.
Over-torque (110% of max. torque range) may cause breakage or accuracy lose. If wrench displays
“ErO”,
this wrench has ever been applied more than 110% of max. torque. Damages are not covered by warranty.
Maintenance and storage
:
-
Do not shake violently or drop wrench. Do not use as a hammer.
-
Do not leave in any place exposed to excessive heat, humidity, or direct sunlight. Do not use in water (not
waterproof). If wrench gets wet, wipe it immediately.
-
Do not use organic solvents when cleaning this wrench.
-
Keep away from magnets.
-
Do not expose to dust, sand, or salt.
-
Do not apply excessive force on LCD display.
-
Apply torque slowly and grasp the center of the handle. Do not apply load at the end of handle.
-
If the torque wrench does not function normally, loosen the battery cap then tighten it to re-start.
-
One-year periodic recalibration is recommended. Please contact your local specialist.
VAR
does not
recalibrate torque wrenches.
-
DV-12100 only
: when checking accuracy or during calibration, please use the bit head packed inside the
blow mold case.