Read all instructions and information in this instruction book and any other literature 
included in the carton referring to this product before operating or using this appliance.

Unpack the appliance and make sure that it is intact and undamaged (fig.1 – page 12). In 
case of any doubt do not use the appliance and contact an expert technician.

Before connecting the appliance to the main power source make sure that rating power 
source from the outlet socket corresponds to the technical data of the appliance which can 
also be found on the data sticker placed on the bottom of appliance. (fig.2 – page 12)

Do not touch hot surfaces (i.e. steam wand). Use handles or knobs.

To protect against fire, electric shock and personal injury, do not place cord, plug or the 
appliance itself in water or any other liquids. (fig.3 – page 12).

Keep out of reach of children and never leave the appliance unattended (fig.4-5 page 12).

The appliance must not be unplugged by pulling the cord or the appliance itself. (fig.6 – 
page 12). Unplug the appliance from outlet socket by pulling the cord plug. 

Before plugging in the appliance to the outlet make sure that the main switch is in the OFF 
position. 

Always turn the appliance OFF before unplugging. 

The appliance should be used indoor and should not be exposed to atmospheric agents i.e. 
direct sunlight, rain, frost, etc. fig.7 – page 12.

Do not allow the cable cord to rub against sharp edges or to be squashed in doors, drawers, 
etc. (fig.8 – page 12).

Do not overturn or tilt the appliance when on (fig.9 – page 12).

Before using the appliance always check the power cable cord is in good condition and 
undamaged.

Always keep your hands away from the jet of steam. This can cause sever scalding (fig.10 – 
page 12).

Always unplug from the mains (fig.11 – page 12):
- before cleaning the appliance or do any boiler cleaning and maintenance.
- when stop using it, even for a short pause.

The appliance is equipped with thermal safety valve: if this valve must be replaced, the 
repair must be carried out by a qualified technician.

Should the appliance be damaged and/or malfunctioning, it must be switched OFF 
immediately and not be used without consulting the Vapor Clean service center. For any 
necessary repairs, please contact the service center (fig.12 – page 12). If the appliance is 
tampered with in any way, the warranty shall be null and void.

Do not use the steam to clean other electrical appliances (fig. 14 – page 12), even if they are 
not connected to the main electric power source.

Never put detergents, perfumes or any other natural or chemical substances into the water 
refilling boiler. (fig. 15 – page 12).

Fill the boiler with only water.

The use of other accessories which are not recommended by the appliance's manufacturer 
may cause problem in fire, electric shock or personal injury.

Do not let the power cord hang over the edge of a table or a counter, do not put it in touch 
with hot surfaces. The use of an extension cord is not recommended, but if it is necessary to 
have one please use at least a 14 gauge commercial extension cord. Anything higher is not 
strong enough and can put an electrical strain on the appliance. 

Do not place the appliance on or near a hot gas or electric burner, or in a heated oven.

6

Содержание II

Страница 1: ...VAPOR CLEAN II An Italian Steam cleaner ...

Страница 2: ......

Страница 3: ...NTS 4 ACCESSORIES 4 TECHNICAL DATA 5 WASTE AND RECYCLING 5 SAFETY REGULATIONS 6 HOW TO USE 8 STARTING UP 8 USING THE ACCESSORIES 9 AFTER STEAM CLEANING 10 LIMESTONE REMOVAL 10 MAINTENANCE AND CLEANING 10 LEGAL ASPECTS 10 GUARANTEE CONDITIONS 11 3 ...

Страница 4: ... orange warning light 6 Steam Regulator Knob 7 Pressure gauge 8 Steam hose socket 9 Electric power cord 10 Swivel castor wheels ACCESSORIES A Rectangular brush with clips B Triangular brush C Window Squeegee E 2 Extension wands F Jet nozzle G Flexible hose with handle H Scraper Spatula I Small round detail brush J Fill cup L Hexagonal drainage key 4 ...

Страница 5: ...d Abusive disposal of the product by the user instigates the application of sanctions according to Leg Decree no 22 1997 article 50 and following of Leg Dec no 22 1997 Data specifications and equipment which are described in this document are not binding and may be altered without prior notice DEAR CUSTOMER We compliment you on the excellent choice you have made by purchasing the Vapor Clean II th...

Страница 6: ...hen on fig 9 page 12 Before using the appliance always check the power cable cord is in good condition and undamaged Always keep your hands away from the jet of steam This can cause sever scalding fig 10 page 12 Always unplug from the mains fig 11 page 12 before cleaning the appliance or do any boiler cleaning and maintenance when stop using it even for a short pause The appliance is equipped with...

Страница 7: ...r cleaning STARTING UP SUGGESTIONS To preserve the appliance we recommend using distilled water reverse osmosis normal city tap water spring water or bottled drinking water Do not use water filtered through a water softener Open the safety cap and fill the boiler with a maximum of 1 6 liters of water fig 16 page 13 Close the cap Lift the main unit socket lid fig 19 page 7 and insert the connector ...

Страница 8: ...p and fill the boiler with water The machine may be left on when filling the machine USING THE ACCESSORIES All the accessories can be fitted directly onto the handle or onto the extension tubes Caution check that the surfaces and the fabrics that you wish to steam clean are suitable for this type of treatment before starting to clean them Rectangular floor brush with clips can be used with or with...

Страница 9: ...ely before putting it away You do not need to empty your machine after if it is being used on a weekly to two week basis LIMESTONE REMOVAL In order to guarantee the maximum duration of the appliance we recommend to empty the boiler each 6 12 months by dismantling the lid of the drainage nut positioned in the bottom part of the appliance fig 27 page 13 and by unscrewing the nut with the equipped dr...

Страница 10: ...hich must be kept and presented in the case of assistance requested from the authorized Service Center 2 The guarantee is understood to cover the replacement and or repair free of charge of components of the appliance that are considered to be originally faulty due to a manufacturing defect 3 In the case of an irreparable fault or the repetition of a fault due to the same defect the whole applianc...

Страница 11: ...11 ...

Страница 12: ...12 ...

Страница 13: ...13 ...

Страница 14: ......

Страница 15: ...Phone number 1 800 758 3141 website www myvaporclean com ...

Отзывы: