I N S T A L L A T I O N
©Vantage, 8/10/2016 / IS-0496-B
Standard Low Voltage Keypad — MODEL: KS1XXX-XXXX
page 2 of 2
Avoid Ground loops with
Auxiliary Connections
Auxiliary connections to the
station are wired to a pigtail,
including motion detectors, door
contacts, light sensors, etc. Each
aux. connection supplies a 15mA
@ 12V DC power source,
eliminating the need for an
external power supply. Aux.
sensors using their own power
should be isolated when
connected to the Black pigtail
wire.
Pigtail for sensors,
dry contacts, etc.
Joining Stations Together
With the EasyGang station design multiple stations easily snap
together to build multi-gang stations.
1.
Carefully break off the left, right or both tabs when
ganging stations.
NOTE:
only break both tabs off on inside stations, with
three or more gangs.
2.
Align the two stations being joined making sure that
UP is the same for
both stations.
3.
Carefully align
locking groves to
mesh correctly.
4.
Gently press the
two halves together
until they lock. The
joined stations may
then be
straightened to
secure the lock.
Multi-View Line Drawing