background image

 

I N S T A L L A T I O N

 

©Vantage, 8/10/2016 / IS-0496-B 

Standard Low Voltage Keypad — MODEL: KS1XXX-XXXX 

page 2 of 2 

Avoid Ground loops with 
Auxiliary Connections 
Auxiliary connections to the 
station are wired to a pigtail, 
including motion detectors, door 
contacts, light sensors, etc. Each 
aux. connection supplies a 15mA 
@ 12V DC power source, 
eliminating the need for an 
external power supply. Aux. 
sensors using their own power 
should be isolated when 
connected to the  Black pigtail 
wire. 

Pigtail for sensors, 
dry contacts, etc. 

 

Joining Stations Together 
With the EasyGang station design multiple stations easily snap 
together to build multi-gang stations. 

1.

 

Carefully break off the left, right or both tabs when 
ganging stations. 

 

NOTE: 

only break both tabs off on inside stations, with 

three or more gangs. 

2.

 

Align the two stations being joined making sure that 
UP is the same for 
both stations. 

3.

 

Carefully align 
locking groves to 
mesh correctly. 

4.

 

Gently press the 
two halves together 
until they lock. The 
joined stations may 
then be 
straightened to 
secure the lock. 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
Multi-View Line Drawing 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 