background image

 

I N S T A L L A T I O N

 

 

©Vantage, 11/6/2014 / IS-0602-A 

InFusion Controller II — MODEL: IC-36-II & IC-24-II 

page 6 of 7 

Connecting Design Center With Security Enabled 

1.

 

If the 

Security Level

 is set to 

None,

 connecting to 

controller proceeds normally. 

2.

 

If the 

Security Level

 is 

set to 

Remote,

 local 

connections proceed 
normally while remote 
connections require 
proper credentials. 

3.

 

With security enabled 
Design Center prompts 
for a user name and 
password. 

a.

 

Entering an Incorrect user name 
and/or password results in an 

Invalid Credentials 

message. 

4.

 

If authentication is accepted, the 
username and password are not required again while the 
project is open and the IP address remains the same. 

Ethernet Connection 

5.

 

The dealer will be allowed to choose if they want a secure 
connection or an unsecured connection. For remote 
connections forward ports to the IP address of the 
InFusion Controller. 

a.

 

Secured ports (SSL) are: 2010, 3010 

b.

 

Standard ports are: 2001 and 3001 

 

Temporary Security Override 

1.

 

A Security override feature exists on the controller 
through the panel buttons on the front of the Controller. 

a.

 

From controller press 

Exit

 until 

the controller is back to screen 1, 
the Home page. From the Home 
page press and hold 

Exit

 for 

about 6 seconds – until the screen changes. 

b.

 

Press 

Adj

 to change security setting to 

None

 or 

Remote

. Press 

Set

 to commit change. The change 

will be active until system is reprogrammed. Pressing 
the 

Exit

 button without making changes cancels the 

controller screen without saving changes. 

c.

 

NOTE: If security has not already been programmed 
on the controller, adjusting the security setting via 
the controller buttons does not do anything. 

 

BACKUP AND RESTORE 

Using backup and restore

 

The backup and restore feature requires that one or more 
controllers on the system contain a micro SD Card. 

 

Recommendation: The Controller used to connect Design 
Center contains the system’s micro SD card. 

 

Recommendation: Install one micro SD card per system. 

 

Backup and Restore From Design Center 

1.

 

In Design Center click on 

System

 | 

Backup And Restore

 

and select from: 

a.

 

Full System Backup 

b.

 

Full System Restore 

c.

 

Restore Equinox Data From Backup.  

i.

 

Option “c”, restores Equinox profile information 
on controller and opens programming screen.   

2.

 

If Backup is selected the system writes the current 
controller programming to the micro sd card. 

3.

 

If Restore is selected the system opens a selection menu.

 

 

a.

 

Last Week 

b.

 

Last Month 

c.

 

Last Quarter 

d.

 

User Initiated (only 
shows when a 
manual backup 
operation has 
been selected) 

e.

 

Choose Backup by Date 

 
4.

 

Choose Backup by Date 
opens a complete 
history. 

5.

 

These same operations 
may be performed from 
the controller via the 
front panel buttons. See 

InFusion Controller 
Front Panel Button 
Operation

 (above). 

 
 

ENHANCED EMAIL 

Expanded Email Options

 

1.

 

Design Center 3.3 comes with new controller firmware 
containing enhanced email support. 

a. Gmail

c. Outlook.com

b. Yahoo

d. Etc. 

NOTE: IC-1 and IC-II could differ in email support – IC-1 has 
a smaller 

OpenSSL

 library do to memory restrictions. Test 

to verify email operation on all email services. 

2.

 

In Design Center click on 

Settings

 and select  

Project Information

 
 
 
 
 
 

3.

 

In the 

Project Information

 window, select the 

Email

 tab to 

open the email setup window. 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
4.

 

The 

Server Address

 is the SMTP server information, for 

example, 

smtp.gmail.com

. The correct SMTP server 

information is needed for the Email service being used. 
Please check with the email service provider for the 
specific SMTP Server information. 

5.

 

The 

User Name

 is the user name used when setting up an 

email account, for example, 

[email protected]

6.

 

Finally the 

Password

 is the password required to access 

your email account. 

7.

 

Click OK when finished.  

8.

 

Tasks may be assigned to send emails as part of their 
execution process. NOTE: Email setup in any Design 
Center project helps the project be future ready for new 
features. 

9.

 

In Design Center select 

Communication | Messaging | Send 

Email

.  

 
 
 

Содержание InFusion Controller II

Страница 1: ...hernet 15 Controllers maximum on each Controller to Controller Bus run InFusion Controller Specifications Description Specification Dimensions HWD 6 62 x 7 88 x 3 0 168mm x 200mm x 76mm Description Specification Weight 24V 3 55 lbs or 1 61 kg Weight 36V 4 4 lbs or 2 kg Voltage 120 240V 50 60Hz Lightning Surge Protection Static Shock IO All ports case IEC 61000 4 2 Low Voltage ITU T K 20 Max Length...

Страница 2: ...ler If the IP address is correct change the connection to standard Ethernet and re download the controller firmware This procedure will also require the system to be re programmed after the firmware update Updating all controllers firmware shipped with Design Center 3 3 or higher should clear this error for future SSL connections Remote Programming and Maintenance Remote programming and update cap...

Страница 3: ...in the Design Center project file for future connections through Ethernet SCREEN 7 CONTROLLER INFORMATION This screen shows information about the IC Uptime the amount of time the IC has been operating without losing power reported in days hours minutes RAM Free Memory Total Memory o RAM This is the active memory Random Access Memory and is volatile Flash Free Memory Total Memory o Flash memory is ...

Страница 4: ...I N S T A L L A T I O N Vantage 11 6 2014 IS 0602 A InFusion Controller II MODEL IC 36 II IC 24 II page 4 of 7 ...

Страница 5: ...ecurity Level is set to None and no Users and Devices exist If the security level is changed to Local or Remote at least one Admin user must be added before exiting the dialog box 4 To create a user press Add User The Add New User dialog box opens 5 Enter a Username and Password and select Admin or User to assign a group 6 Press Add to add the new user a Admin have all permissions selected by defa...

Страница 6: ...ect Design Center contains the system s micro SD card Recommendation Install one micro SD card per system Backup and Restore From Design Center 1 In Design Center click on System Backup And Restore and select from a Full System Backup b Full System Restore c Restore Equinox Data From Backup i Option c restores Equinox profile information on controller and opens programming screen 2 If Backup is se...

Страница 7: ...ard may produce a ground loop Often the third party connected RS 232 RS 485 device is not using the same power source or is far away from the Vantage enclosure resulting in a possible ground loop or data noise condition If this condition is suspected Vantage recommends a third party RS 232 RS 485 Opto optical Isolation connection Opto Isolation provides a communications link and is an important co...

Отзывы: