background image

www.fmiproducts.com

125524-01A

10

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Log 

Size Height Depth

Front 

Width

Rear 

Width*

18"

17"

13.5"

20"

14"

24"

17"

13.5"

26"

18"

30"

21"

13.5"

32"

22"

36"

21"

13.5"

38"

27 

1

/

2

"

*Measured at 13.5" depth

CHECK GAS TYPE

Use the correct type of gas (natural or propane/

LP). If your gas supply is not the correct gas 

type, do not install heater. Call dealer where 

you bought heater for proper type heater.

 WARNING: This appliance is 

equipped for either natural gas 

or propane/LP gas but not both. 

Gas type is indicated on the rat

-

ing plate. Field conversion is not 

permitted.

INSTALLATION AND CLEARANCES 

FOR VENT-FREE OPERATION

  WARNING:  Maintain  the 

minimum  clearances.  If  you 

can, provide greater clearances 

from floor, ceiling and adjoining 

wall.

Minimum Fireplace Clearance to 

Combustible Materials

Side Wall 16", Ceiling 42", Floor 5",

Front 36"

INSTALLATION

Continued

Carefully follow these instructions. This will 

ensure  safe  installation  into  a  masonry, 

UL127-listed manufactured fireplace or listed 

vent-free firebox.

Minimum Clearances For Side 

Combustible Material, Side Wall and 

Ceiling

A.  Clearances from the side of the fireplace 

cabinet to any combustible material and 

wall should follow diagram in Figure 4.

Figure 4 - Minimum Clearance for 

Combustible to Wall

*Minimum 16" from Side Wall 

*

Example

 

Example:

 The face of a mantel, bookshelf, 

etc. is made of combustible material and 

protrudes 3 

1

/

2

" from the wall. This com-

bustible material must be 4" from the side 

of the fireplace cabinet (see Figure 4).

 

Note: When installing your gas logs into 

a  manufactured  firebox,  follow  firebox 

manufacturer’s instructions for minimum 

clearances to combustible materials.

B.  Clearances from the top of the fireplace 

opening to the ceiling should not be less 

than 42".

NOTICE: Manual control heaters 

may be used as a vented product. 

If so, you must always run heater 

with chimney flue damper open. 

If  running  heater  with  damper 

open, noncombustible material 

above fireplace opening is not 

needed. Go to 

Installing Damper 

Clamp  Accessory  for  Vented 

Operation

, page 12.

Содержание BG18NM

Страница 1: ...pplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer s...

Страница 2: ...urning masonry or UL127 factory built fireplace or in a listed ventless firebox enclo sure It is design certified for these installations in accordance with ANSI Z21 11 2 Exception Do not install this...

Страница 3: ...ts Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater or its controls ca...

Страница 4: ...sed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Make sure there are no obstructions across openings of fireplace 8 To prevent the creation of soot f...

Страница 5: ...grate as sembly The data plates contain important warranty and safety information 1 Remove logs and heater base assembly from cartons Note Do not pick up heater base assem bly by burners This could d...

Страница 6: ...ld air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must...

Страница 7: ...enings add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support _________ volume of space x 20 Maxi mum Bt...

Страница 8: ...ure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grill...

Страница 9: ...oisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventila tion page 6...

Страница 10: ...ensure safe installation into a masonry UL127 listed manufactured fireplace or listed vent free firebox Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearances from the si...

Страница 11: ...s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With sheet metal you must have noncombustible material be hind it Noncombustible materia...

Страница 12: ...el you must maintain the minimum distance of 14 to combustibles see Figure 8 B If combustible materials are less than 14 to the fireplace you must install appliance at least 5 above the combustible fl...

Страница 13: ...al Makesurematerial is secure CAUTION Do not pick up heater base assembly by burn ers This could damage heater Only handle base assembly by grates IMPORTANT Make sure the heater burners are level If h...

Страница 14: ...Base to Fireplace Floor Masonry Screw CONNECTING TO GAS SUPPLY WARNING A qualified ser vicepersonmustconnectheater to gas supply Follow all local codes CAUTION Never connect propane LP fireplace dire...

Страница 15: ...ed matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not...

Страница 16: ...in gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming...

Страница 17: ...WARNING Failure to posi tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury Log Suppo...

Страница 18: ...t Log Figure 20 Installing Log Sets Middle Right Log Middle Left Log Bottom Log Pin on Front Left Log Figure 21 Installing LBG36 SM Model Control Cover Logs Left Control Cover Log Right Control Cover...

Страница 19: ...its shape and much lighter weight when compared to the other logs Figure 23 Installing Log Set Base Assembly Ramp Log Figure 24 Installing Log Set Ramp Log Metal Tab 2 The log must sit flat on the bla...

Страница 20: ...ly in place as shown in Figures 27 28 Do NOT place ember material anywhere else on the unit Use only ember ma terial supplied with unit Exces sive or incorrectly placed ember material may produce carb...

Страница 21: ...replac ing see Parts page 32 Platinum Bright Ember placement Add embers to front flat burner Gently remove embers from bag Separate pieces of ember material and place on surface of flat burner just be...

Страница 22: ...nitor Button Location Control Knob Electronic Ignitor Button for your safety read before lighting WARNING If you do not fol low these instructions exactly a fire or explosion may result causing proper...

Страница 23: ...ve pilot lit and shut off burners only turn control knob clockwise to the HI position Press in and turn control knob clockwise to the PILOT position Figure 32 Pilot Ignitor Electrode Thermocouple Pilo...

Страница 24: ...Your pilot may vary from pilots shown Thermocouple Thermocouple Pilot Burner FRONT BURNER FLAME PATTERN Figure 35 shows correct front burner flame pattern Figure 36 shows incorrect front burner flame...

Страница 25: ...r to each heating season Blocked air holes will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person We a...

Страница 26: ...lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Cleaning AND MAINTENANCE Continued LOGS If you remove logs for cleaning refer to I...

Страница 27: ...n PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor...

Страница 28: ...ntrol knob pressed in 30 seconds 3 Fully open equipment shut off valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 25 or replace ODS pilot a...

Страница 29: ...let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 throug...

Страница 30: ...g statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defec...

Страница 31: ...ural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C BG2436pM Rating Variable 24 000 35 000 Btu Hr Type Gas Propane LP Ignition Electronic Manifold...

Страница 32: ...www fmiproducts com 125524 01A 32 PARTS Variable Manual control Models BG18NM BG18PM BG2436NM BG2436PM 1 3 13 5 16 27 19 18 17 14 6 9 2 4 24 11 25 12 10 8 7 20 15 21 22 23 26 28...

Страница 33: ...3242 02 Rear Ramp Burner 1 13 112713 01 Pilot Bracket 1 112713 03 Pilot Bracket 1 14 098276 01 Plug 1 15 112782 02 Air Deflector Bracket 1 112782 03 Air Deflector Bracket 1 16 125003 01 Air Shield 1 1...

Страница 34: ...66 01 Flex Tube 1 100563 01 Warning Plate 1 101055 02 Lighting Instruction Plate 1 100639 12 Caution Decal 1 101137 02 Hardware Kit 1 GA6060 Lava Rock 1 125527 01 Left Ember Chunk 1 1 125527 02 Middle...

Страница 35: ...ectronic Ignitor 1 11 112465 01 Front Ramp Burner 1 112465 02 Front Ramp Burner 1 12 113242 01 Rear Ramp Burner 1 113242 02 Rear Ramp Burner 1 13 112713 01 Pilot Bracket 1 112713 03 Pilot Bracket 1 12...

Страница 36: ...og 1 3 121699 02 121699 08 121699 14 Middle Right Log 1 4 121699 03 121699 09 121699 15 Middle Left Log 1 5 121699 01 121699 13 121699 13 Bottom Log Remote 1 6 121699 06 121699 12 121699 18 Rear Log 1...

Страница 37: ...699 21 Front Right Log 1 6 121699 22 Back Log 1 7 121699 23 Left Small Front Log 1 8 121699 24 Right Small Front Log 1 9 121699 25 Left Control Cover Log 1 10 121699 26 Right Control Cover Log 1 1 2 3...

Страница 38: ...055 10 Middle Right Log 1 4 125055 16 125055 05 125055 11 Middle Left Log 1 5 125056 01 125056 02 125056 02 Ramp Log 1 6 125055 14 125055 03 125055 09 Rear Log 1 7 125055 06 125055 06 125055 06 Top Lo...

Страница 39: ...For all models Includes lava rock burner embers and burner cinders Control Cover Kit CC100 For all models Includes control cover log and 6 unique fall away logs Technical Service You may have further...

Страница 40: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Отзывы: