TABLET HOPPER

1.  Unplug any solenoid valves (if applicable) and turn the water supply to the feeder off.

2.  Open the top and remove any remaining tablets in the hopper and place into a clean dry pail.

3.  Rinse, brush, and clean out the tablet hopper and tablet tray with water.  

SOLUTION TANK

1.  When all parts have been cleaned  and washed thoroughly with water, the interior of the tubing,

tablet hopper, solution tank and eductor (if applicable) can be cleaned by adding a mild solution
of acid to the feeder and allowing it to be drawn through the piping by the action of the eductor.

DANGER:

Be sure that all chlorine has been removed from the feeder prior to addition of

any product containing acid. Mixing of chlorine and muriatic acid can produce hazardous
conditions leading to personal or bodily injury.

2.  Rinse, brush and clean out the solution chamber with fresh water.

3.  Rinse brush and clean all feeder parts with fresh water.  

4.  After addition of acid to the feeder, allow the feeder to operate with fresh water for several cycles

to remove all acid from the feeder.  All acid must be removed from feeder prior to the addition of
chlorine.

5. Refill feeder with appropriate amount of Vantage Calcium Hypochlorite Tablets, replace feeder lid,

plug in solenoid valve (if applicable,) turn on water and adjust flow rate for proper chlorine output.

6.  Check feeder operation to ensure feeder is working properly.

Hazardous conditions to avoid:

DURING BACKWASHING CYCLE

Prior to beginning the backwash cycle, turn booster pump off and close the inlet and outlet ball
valves to prevent water flow into the feeder during the backwash cycle.  Once backwashing cycle is
completed, return valves to previous setting and resume booster pump operation.  

SHOCKING OR SUPERCHLORINATING

Prior to the application of shock or superchlorinating product to the pool, close the inlet and outlet
ball valves to prevent water flow into the feeder.  Do not reopen valves for at least 2 hours following
application of shock or superchlorinating product to prevent contamination of tablets.

WINTERIZATION OF FEEDER

If the pool circulation system is shut down during the winter the following procedures are recom-
mended:

1.  Operate the feeder until all the Vantage Calcium Hypochlorite Tablets are dissolved. 
2.  Flush the feeder with fresh water.  Follow cleaning procedures to remove any residue in the

feeder.

3.  Drain feeder completely of water.  
4.  Disconnect feeder from power and water supply.  
5.  Store feeder out of sun in a clean, dry location.  

Содержание ACF-8

Страница 1: ...Installation and Operation Manual ACF 8 Automatic Chlorinating Feeder...

Страница 2: ......

Страница 3: ...and supplies may be supplied by the installer The recommended optional installation parts are the ACF 8 Installation kit P008100 includes 25 feet of 5 8 o d tubing four tubing connectors Vantage 1 2 E...

Страница 4: ...nd rain This feeder should be installed on a flat level surface capable of supporting its weight when full This feeder is designed to operate at an inlet pressure of 10 45 psi The flow rate will be co...

Страница 5: ...rculation pump and the feeder should be elevated above the level of the circulation pump This installation method may result in some air being drawn back into the circulation pump and possibly returne...

Страница 6: ...he influent flow is greater then the effluent flow and water will overflow out the overflow drain 6 Prior to filling feeder read First Aid Precautionary Statements Directions for Use and Storage and D...

Страница 7: ...o Injector 1 2 Feeder Inlet Inlet Ball Valve Pressure Gravity Installation Figure 1 ACF 8 sump surge pit balance tank or collection tank Effluent feed line Return line Flow Meter Solenoid to controlle...

Страница 8: ...r Inlet Water Flow From Pool Isolation Valve Check Valve Pool Return Ball Valve 1 2 Venturi w check valve Flow Meter Flow Control Valve optional 1 2 Solenoid to Controller P OOL P UMP F ILTER Modified...

Страница 9: ...Feeder Inlet Water Flow From Pool Isolation Valves Pool Return Ball Valve Ball Valve Venturi w check valve Flow Meter Solenoid to controller if applicable H EATER if present P OOL P UMP F ILTER ACF 8...

Страница 10: ...1 Overflow to waste 1 2 Feeder Inlet Return line Flow Meter Solenoid to controller if applicable Inlet Ball Valve Outlet Ball Valve Flow Pump strainer Pressure Suction Installation Figure 4 ACF 8...

Страница 11: ...5 Refill feeder with appropriate amount of Vantage Calcium Hypochlorite Tablets replace feeder lid plug in solenoid valve if applicable turn on water and adjust flow rate for proper chlorine output 6...

Страница 12: ...Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and under no...

Страница 13: ...VTGACF8IOM 060507 Copyright 2014 Document Version 01 AllChem Performance Products...

Отзывы: