background image

FACTORY SUPPLIED INSTALLATION PARTS

25’ – 5/8” Tubing
4 – ½” npt x 5/8” tubing adapters 
1- ½” In-line strainer
2- ½” solenoid valves
Flow Meter

INSTALLER SUPPLIED PARTS

Due to the wide variety of installations possible, AllChem Performance Products, LP can not supply all parts and
pieces required for installation.  Some commonly available plumbing parts and supplies may be supplied by the
installer.

REPLACEMENT PARTS

Feeder Assembly

Part Number

Complete ACF-250 Feeder

E023250VTG

Part Description

Part Number

½” Solenoid Valve

P2002201

Flow Meter

P2002202

In-Line Strainer

P2002203

25’ of 5/8” OD Tubing

P2002225

Feeder Discharge Assembly 

(discharge valve body, discharge fitting and locking bolt)

P601204

Chlorine Feed Assembly

(sieve plate, legs, overflow)

P2501400

Float Assembly

P601206

Eductor Model 3144         

P2001207

Check Valve                    

P2001208

Booster Pump (3/4 hp)      

P2001209 

Inlet Flow:

2.0 - 3.5 gpm

Outlet Flow:

= Inlet Flow

Inlet Pressure:

10 - 45 psi

Maximum Output: 

200 lbs. of Available Cl

2

per Day

Capacity: 

250 lbs. of Vantage® Calcium Hypochlorite Tablets

Feeder Height

43.5”

Feeder Width

21”

Feeder Depth

27”

Feeder weight (full)

320 lbs.

Feeder weight (empty)

70 lbs.

Tubing

5/8” O.D.

For Swimming Pool Use Only

Recommended Pool Size

(US Gallons)

up to 1,000,000 Gallons

Operating Specifications

1

Содержание ACF-250

Страница 1: ...Installation and Operation Manual ACF 250 Automatic Chlorinating Feeder...

Страница 2: ......

Страница 3: ...er P2002202 In Line Strainer P2002203 25 of 5 8 OD Tubing P2002225 Feeder Discharge Assembly discharge valve body discharge fitting and locking bolt P601204 Chlorine Feed Assembly sieve plate legs ove...

Страница 4: ...ing 4 Float Valve Body 5 Float Assembly 6 Chemical Feed Solenoid Valve 7 Supply Manifold 8 Inlet Water Solenoid Valve 9 Rinse Nozzle 10 Level Switch Assembly 11 Chemical Tank Lid Chlorine Feed Assembl...

Страница 5: ...at an inlet pressure of 10 45 psi The flow rate will be con trolled in the range of 2 0 to 3 5 gpm CONNECTING THE ACF 250 RECOMMENDED INSTALLATION METHODS SIDESTREAM WITH BOOSTER PUMP AND VENTURI see...

Страница 6: ...desir able in some applications to install the venturi without the use of a booster pump The sidestream is created by using the pressure differential created across the pools filter and heater The sid...

Страница 7: ...uitable piping connections to the suction side of the pools circulation pump It may be necessary to make specific valve adjustments so that the feeder will not be com pletely drained by the suction of...

Страница 8: ...Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer 1 2 Feeder Inlet H EATER if present P OOL P UMP B OOSTER P UMP F ILTER denotes PVC piping denotes...

Страница 9: ...er Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer Flow Control Valve optional H EATER if present P OOL P UMP F ILTER denotes PVC piping denotes...

Страница 10: ...he influent and effluent flow as necessary In some situations it may be desirable to adjust the float valve in the solution tank using the bolt located on the float valve arm For detailed instructions...

Страница 11: ...oat assembly and other parts can be damaged with rough handling Use caution when cleaning these parts 4 When all parts have been cleaned the interior of the tubing venturi check valve and venturi can...

Страница 12: ...alves to prevent water flow into the feeder Do not reopen valves for at least 2 hours following application of shock or superchlorinating product to prevent contamination of tablets WINTERIZATION OF F...

Страница 13: ...peration Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and...

Страница 14: ...VTGACF250IOM 060507 Copyright 2007 Document Version 01 AllChem Performance Products LP...

Отзывы: