background image

9

LIMITED WARRANTY

AllChem Performance Products hereby warrants, subject to the conditions set below, that

should the Vantage® ACF-250 Automatic Chlorinating Feeder or any component part included with the
ACF-250 prove defective by reason of improper workmanship or material from the original date of retail
purchase and up to one year thereafter; AllChem Performance Products, LP will replace the defective
part(s) upon receipt of those same part(s) from the purchaser.  AllChem Performance Products, LP will
not pay for any labor or shipping costs incurred in the removal or replacement of those parts.

CONDITIONS

1.  Registration: the registration card included must be filled out completely and forwarded to AllChem

Performance Products, LP, 6010 NW First Place, Gainesville, FL 32607 within 30 days of installa-
tion.

2.  Notification:  the purchaser must notify AllChem Performance Products, LP within 30 days after dis-

covery of part failure, stating which part(s) were defective or broken.

3.  Use of unauthorized chemicals:  Only 

VANTAGE® Calcium Hypochlorite Tablets

(EPA Reg. No.

69681-14) should be placed in a Vantage® Automatic Chlorinating Feeder.  Use of any other chem-
ical may lead to hazardous conditions and will void this warranty.  

4.  Installation and operation of the warranted equipment must be in accordance with the instructions

contained in the Installation and Operation Manual.  Should the warranted equipment prove defec-
tive in workmanship or material, the consumer’s sole remedy shall be replacement of defective
parts as is herein above expressly provided:  and under no circumstances shall AllChem
Performance Products, LP be liable for any loss or damage direct or consequential arising from the
use of the warranted equipment.  

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limita-
tion of accidental or consequential damages, so the above limitation or exclusion may not apply.  This
warranty gives the purchaser specific legal rights and (s)he may also have other rights, which vary,
from state to state.  

For technical support, please call 352-333-7317

Fill out the warranty information on the card below 

in black ink

and mail within 14 days of Product

Purchase/Installation to:

AllChem Performance Products, LP

6010 NW First Place

Gainesville, FL 32607

Attn: Warranty Dept.

ACF-250 W

ARRANTY

R

EGISTRATION

C

ARD

Facility Name

_______________________________________________________

Physical Address

_____________________________________________________

City

_____________________________  

State

________  

Zip

_______________

Facility Contact

_________________ 

E-Mail Address

___________________________

Purchased From

_________________________

Installed By

___________________________  

Date of Installation

_________________

Product Model

_______________  

Product Serial Number

________________________

 

New Installation

Replacement Installation

Pool Volume

___________________   

 

Indoor

Outdoor

Содержание ACF-250

Страница 1: ...Installation and Operation Manual ACF 250 Automatic Chlorinating Feeder...

Страница 2: ......

Страница 3: ...er P2002202 In Line Strainer P2002203 25 of 5 8 OD Tubing P2002225 Feeder Discharge Assembly discharge valve body discharge fitting and locking bolt P601204 Chlorine Feed Assembly sieve plate legs ove...

Страница 4: ...ing 4 Float Valve Body 5 Float Assembly 6 Chemical Feed Solenoid Valve 7 Supply Manifold 8 Inlet Water Solenoid Valve 9 Rinse Nozzle 10 Level Switch Assembly 11 Chemical Tank Lid Chlorine Feed Assembl...

Страница 5: ...at an inlet pressure of 10 45 psi The flow rate will be con trolled in the range of 2 0 to 3 5 gpm CONNECTING THE ACF 250 RECOMMENDED INSTALLATION METHODS SIDESTREAM WITH BOOSTER PUMP AND VENTURI see...

Страница 6: ...desir able in some applications to install the venturi without the use of a booster pump The sidestream is created by using the pressure differential created across the pools filter and heater The sid...

Страница 7: ...uitable piping connections to the suction side of the pools circulation pump It may be necessary to make specific valve adjustments so that the feeder will not be com pletely drained by the suction of...

Страница 8: ...Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer 1 2 Feeder Inlet H EATER if present P OOL P UMP B OOSTER P UMP F ILTER denotes PVC piping denotes...

Страница 9: ...er Flow From Pool Isolation Valves Pool Return Venturi w check valve Inlet Ball Valve Flow Meter Strainer Flow Control Valve optional H EATER if present P OOL P UMP F ILTER denotes PVC piping denotes...

Страница 10: ...he influent and effluent flow as necessary In some situations it may be desirable to adjust the float valve in the solution tank using the bolt located on the float valve arm For detailed instructions...

Страница 11: ...oat assembly and other parts can be damaged with rough handling Use caution when cleaning these parts 4 When all parts have been cleaned the interior of the tubing venturi check valve and venturi can...

Страница 12: ...alves to prevent water flow into the feeder Do not reopen valves for at least 2 hours following application of shock or superchlorinating product to prevent contamination of tablets WINTERIZATION OF F...

Страница 13: ...peration Manual Should the warranted equipment prove defec tive in workmanship or material the consumer s sole remedy shall be replacement of defective parts as is herein above expressly provided and...

Страница 14: ...VTGACF250IOM 060507 Copyright 2007 Document Version 01 AllChem Performance Products LP...

Отзывы: