Features

Thank you for purchasing an Axium 450 series Multi-Zone Amplifi er.
Please read this manual thoroughly before making connections and plugging in the unit.
Following the instructions in this manual will enable you to obtain optimum performance and listening 
enjoyment from your new Multi-Zone Amplifi er.
Please retain this manual for future reference.

Multi-Zone, Multi-Source, Video Switching

The 450 series amplifi er has four separate preamplifi ers 
and amplifi ers, providing 4 zones of independent yet 
integrated control. 
There are seven stereo sources (S1 – S7) and an eighth 
mono source (S8) typically used for paging applications.
Each zone has an eight-source composite video switcher, 
so monitor screen’s in four different rooms may display 
any of the eight sources 
(S1 – S8).

Preamplifi ers and Outputs

Each zone has bass, treble, balance and loudness 
control. These are accessed either from the front panel 
or MC

 

(Music Center) program.

The preamplifi er output volume may be independent 
of the amplifi er volume, or made to track the amplifi er 
with an adjustable offset (± 20dB). The tracking 
feature is ideal for passive subwoofer control, while the 
independent volume feature is useful for limited control 
in close-coupled rooms. 
A useful protection feature is ‘Maximum Volume limiting’. 
This limits the maximum volume of either the amplifi er 
or preamplifi er.  

Amplifi er Power, Protection, and Clipping 
Indicators

50 Watts RMS per channel into 8 ohms, 65Watts RMS 
per channel into 6 ohms. 
The amplifi ers are protected against short-term output 
shorts.
The front panel zone indicators will fl ash red when the 
zone amplifi ers are overdriven into clipping.

Thermal Control

There are three progressive levels of thermal control:

• 

Internal fans are turned on to aid cooling at 50oC.

• 

The amplifi er volume is reduced 20dB at 100oC.

• 

At 105oC the amplifi ers are shutdown until the 

temperature reduces below 50oC. 

Care should be taken to ensure adequate ventilation 
– see “Important safety instructions” on page 1

USB, RS232 and IR control

The 450 series amplifi er may be controlled and 
monitored via either the front Panel USB or rear panel 
RS232 serial interface. 
In multi amplifi er installations where the amplifi ers are 
interconnected using an expansion bus cable, only one 
USB or RS232 connection is required to control the stack 
of amplifi ers.  
A 450 series amplifi er may receive IR directly from the 
front panel receiver or via the two ‘Controller interface’ 
connections. 
There are zone specifi c IR commands and also a set of 
global IR commands. 
The commands are: ON, OFF, Standby (toggling), 
Mute, Amp Volume Up, Amp Volume Down, Pre Volume 
Up, Pre Volume Down, Source Selects, Discrete Audio 
Source Selects, Discrete Video Source Selects, On with 
Source Specifi c commands.
The Global commands also include PRESET1 – PRESET 
6, Alarm Enable, Alarm OFF, & 5 minute Sleep. 

Real Time Clock

The 450 series amplifi er is equipped with a real time 
clock. 
The amplifi er may be set up to function as an alarm 
clock, so that at 6.30am in the morning 5 days a week, 
the master bedroom zone could be made to turn on, 
select tuner, and go to a specifi c volume.  Multiple 
Alarms are feasible ( max of 6) However the Alarm 
Enable & OFF commands act upon all programmed 
Alarms.
The Clock automatically compensates for daylight 
saving. 
The clock continues to operate typically > 48 hours 
without power – more than enough to keep the time 
current during lengthy power outages

.

IR Emitter Ports

There are 4 Buffered IR emitter Ports.
Two IR ports have routing, and are linked to their 
respective ‘Controller Interface’ ports. These ports 
control zone specifi c source components. Two IR ports 
are the sum of both IR sources; these control the All 
zone source components.

Содержание Axium 450 Series

Страница 1: ......

Страница 2: ...it but also ensure that air can flow freely and escape from the amplifier surroundings Failure to do so may cause thermal shutdown of the unit or intermittent channel cutout and reduced life expectanc...

Страница 3: ...he front panel is exposed to direct sunlight may cause control to become sluggish 9 Controller Connection Never connect more than four controllers to the 12VDC power supply terminals The supply is int...

Страница 4: ...Supplied Accessories 4 Installation Guide 5 Features 6 Front Panel Guide 8 Rear Panel Guide 9 Typical System Configuration 10 Controller Termination 12 Advanced IR Control 13 Multiple Amplifier Stacks...

Страница 5: ...right arrow Scroll through the menu and select Set Zone and change to the required assignment pushing the Knob to set 4 Wire the keypads to the rear of the amplifier 5 To setup the keypad follow the...

Страница 6: ...aid cooling at 50oC The amplifier volume is reduced 20dB at 100oC At 105oC the amplifiers are shutdown until the temperature reduces below 50oC Care should be taken to ensure adequate ventilation see...

Страница 7: ...oped 1 5 second mono sounds can be generated as part of a page preset Suitable wav files are uploaded to the unit using the MC program MC truncates the wav files to a suitable size Buffered Video Outp...

Страница 8: ...us are navigated and selections made using left and right rotation and pushes on the knob 5 USB Mini B port The port is used to setup control or monitor the amplifier A USB mini B cable must be used w...

Страница 9: ...y of the zones are ON 8 Input Terminals Audio and Composite Video Source inputs 9 Expansion Bus Input Connects with another 450 series amplifier s expansion bus output provides connection of source eq...

Страница 10: ...10 Typical System Configuration FIG 1...

Страница 11: ...no and seven stereo RCA audio inputs for connecting to source equipment Fig 1 configuration has only six of the possible eight sources populated A zone may select from any of the connected sources Som...

Страница 12: ...ft Note Some IR receivers have an Amplifier On indicator their On terminal should be connected to the zone s AMP ON output not to the controller interface ports Data terminal Orange Green Orange Green...

Страница 13: ...late the radiated IR from interfering with their discrete operation This may be achieved by either installing in different cupboards locations or by using IR blockers over the IR emitters The IR block...

Страница 14: ...bus lead The source equipment audio inputs must be plugged into the first amplifier where they are buffered and sent to the next amplifier in the stack The maximum recommended expansion is eight unit...

Страница 15: ...king could be used to simplify the control of the two otherwise separate zones Zone 2 is simply linked to zone 1 either via the front panel user interface or MC program Once linked both zones will alw...

Страница 16: ...s it s own operating system that is programmed to handle the RS232 protocol An automation system is not restricted to touch panels it may be an extension of a home lighting security building managemen...

Страница 17: ...reset Selection status 26 Volume BCD format 28 Video Source selection Zone Amplifiers and keypads are encoded with up to 32 zones The zone byte is used for checking if the command is applicable to the...

Страница 18: ...Audio only Volume 04 00 A0 range Bass 05 F4 0C 12db 12db Treble 06 F4 0C 12db 12db Balance 07 EC 14 Left 20db Right 20db Send all parameters 09 XX value ignored Amplifier features 0C 00 Loudness enab...

Страница 19: ...it is returned q A Standby ON command implies that the amplifier is not muted if the amplifier was previously Off a mute command must follow the Standby command if it is muted q Not all Command and D...

Страница 20: ...p S4 03 23 43 63 83 A3 C3 E3 Bank 3 Amp S3 04 24 44 64 84 A4 C4 E4 Bank 2 Amp S2 05 25 45 65 85 A5 C5 E5 Bank 1 Amp S1 08 28 48 68 88 A8 C8 E8 Volume Up 09 29 49 69 89 A9 C9 E9 Standby Command 0A 2A 4...

Страница 21: ...eck with your dealer for this procedure Primary Functions Menu If the zone is Off then the clock zone or room name power Off and select room arrow are displayed Selection bars are shown surrounding th...

Страница 22: ...right arrow in the primary function menu accesses the More Functions Menu The available functions are Bass 0dB 12dB of adjustment Treble 0dB 12dB of adjustment Balance 0dB 20dB adjustment to the Left...

Страница 23: ...med Presets C Clear alarms The menu has the following selections Clear alarms Deletes all Alarm Clock programming Preset 1 Creates preset 1 The following setup is the same for all other preset Set Ala...

Страница 24: ...Lockout Yes No To clear the Setup lockout enter enter the Setup Menu by holding down the multi Jog for 10 seconds and enter the password 1396 Password 0 Return When entered returns to the Primary Fun...

Страница 25: ...ol of any amplifier zone The file menu contains the New Window Keypad Window View Amplifier Log Upload Sound and Exit commands New Window Opens another instance of MC s main window This is useful for...

Страница 26: ...te On status The standby buttons may be named with the room name A name edit window is opened by a right click above the standby Button enter the new text and click OK to save and exit The room name i...

Страница 27: ...en the chain symbol is unbroken the preamplifier volume tracks the amplifier volume An offset between the preamplifier and amplifier volume may be made by identifying the volume bar to be changed with...

Страница 28: ...Mode Any one zone may be linked to one other zone by left clicking the Link Zone down arrow and making the selection from the zone list Linked zones have the same source selection Volume and standby m...

Страница 29: ...nd is received The process is the same for all other presets The Preset may be re named Right click on the Preset button in MC s main window Opens the name edit window Enter the new text and click OK...

Страница 30: ...the required time and days that the Alarm is to operate and change all the required settings in MC s main window i e which zones are ON their volume and source selection etc Left click the Default sel...

Страница 31: ...amplifier zone which is in Independent Mode If the Keypad is controlling a Preamplifier zone which is in Independent Mode then Left click Preamp Left clicks on the AX KPB buttons cause the connected K...

Страница 32: ...p 75 Composite Buffered Video Output Level and Impedance S1 S8 1 Vp p 75 Composite Output Level Impedance Z1 Z4 1 Vp p 75 Composite Interface IR Output A B IR1 IR2 3 5mm phone Jack Expansion Bus Input...