Installing The Fireplace Shell
The fireplace may be installed in any location that main-
tains proper clearances to air conditioning ducts, electrical
wiring and plumbing. Safety, as well as efficiency of opera-
tion, must be considered when selecting the fireplace loca-
tion. Try to select a location that does not interfere with
room traffic, has adequate ventilation
Refer to page 4 - B-Vent Installation for more information.
The fireplace dimensions are shown below:
Front View
Side View
Top View
Corner Installation.
Figure 3.
Fireplace dimensions.
34 1/8”
9 3/8”
65 7/8”
32 7/8”
1” clearance
at corners
Clearances
These clearances apply to all dimensions except the framed
opening, where the clearance to combustibles are listed on
Page 6,
Section No. 2
.
The VL36-BN clearances to combustible materials are:
Top
64”
Back
1”
Side
1”
Floor
0”
Mantel
9”
Perpendicular Wall
4”
B-Vent
1”
Clearances specified by the B-vent manufacturer.
For protection against freezing temperatures, it is recommend-
ed that outer walls of the chase be insulated with a vapour
barrier. This will reduce the possibility of a cold-air convection
current on the fireplace.
Figure 4.
Combustible
Shelf location.
35 3/4”
27 1/8”
16 1/4”
4 3/8”
A
A
6 3/4”
1”
Fresh Air
Inlet
14 1/2”
64”
Flue collar
Shelf
Floor /
Hearth
Min.
12’-0”
1”
1”
Back Wall
2” non-
combustible
board
Part. No.
VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 7
Содержание Nova VL36BN
Страница 18: ...Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 18 SIT Millivolts Valve...
Страница 19: ...SIT IPI Valve Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 19...
Страница 20: ...Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 20...
Страница 26: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 26...
Страница 27: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 27...