Introduction

Thank You for choosing a VANOX VL36 Fireplace 

 

  

About the VL36BN Fireplace

 

 

The VL36-BN includes a 18,000 BTU Linear burner. The 

VL36-BN is certified in Canada and USA as a Vented Gas 

Fireplace (ANSI Z21.50 -2014 / CSA 2.22 -2014) and is avail-

able in two versions.

• VL36BN - Millivolt Ignition)

• VL36BN-E - IPI Ignition)

The VL36-BN is rated for Natural Gas at 18,000 BTU/H (7.33 

Kilowatts) Input.

How to use this manual:

This manual covers all models and unless otherwise speci-

fied, the designation VL36-BN refers to all models. Sections 

which are specific to a particular model are marked with a

symbol, plus the appropriate model number.

Warranty and Installation Information:

The Vanox warranty will be voided by, and Vanox disclaims 

any responsibility for, the following actions:

• Modification of the fireplace and/or components includ-

ing glass doors.

• Use of any component part not manufactured or ap-

proved by Vanox in combination with this Vanox fireplace 

system.

• Installation other than as instructed in this manual.

Consult your local Gas Inspection Branch on installation 

requirements for factory-built gas fireplaces. Installation & 

repairs should be done by a qualified contractor.

Installations in Canada must conform to the current CAN/

CGA B149.1 and .2 Gas Installation Code and local regula-

tions.

• Installation in the USA must conform to local codes, or in 

the absence of those codes, conform to the National Fuel 

gas Code, ANSI 2223.1 / NFPA54.

Before you Start

IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS

The VL36BN B- Vent fireplace must be installed in accor-

dance with these Instructions. Carefully read all the Instruc-

tions in this manual first. Consult the Local Gas Branch to 

determine the need for a permit prior to starting the instal-

lation. It is the responsibility of the installer to ensure this 

fireplace is installed in compliance with the manufacturers

instructions and all applicable codes.

Installation

Part. No. 

VL36BN-Man-072414-A

VL36BN Gas Fireplace

VANOX Fireplace Inc.

Page  4

Содержание Nova VL36BN

Страница 1: ...oled Never allow children to touch glass CAUTION Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off Safety screens ar...

Страница 2: ...AVERTISSEMENT Ne pas entreposer ni utiliser d essence ou d autres vapeurs et liquides inflammables proximit de cet appareil ou tout autre appareil de chauffage au gaz Un incendie ou une explosion peu...

Страница 3: ...n 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 3 VL36BN Gas Fireplace Safety Alert Key Introduction 4 Installation Before you Start 4 5 Installation Checklist 5 Section 1 Installation Overvi...

Страница 4: ...proved by Vanox in combination with this Vanox fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requirements for factory...

Страница 5: ...nctionnement lev es cet appareil ne doit pas tre situ hors de la circulation et loin des meubles et des rideaux Les enfants et les adultes doivent tre sensibilis s aux dangers de la temp rature de sur...

Страница 6: ...est point in the B Vent installation 3 Should it be impossible to meet the venting require ments laid out in Section 3 Venting please contact Vanox 4 Lay out the Vent run and Electrical Requirements R...

Страница 7: ...ers Clearances These clearances apply to all dimensions except the framed opening where the clearance to combustibles are listed on Page 6 Section No 2 The VL36 BN clearances to combustible materials...

Страница 8: ...ations as shown Failing to do so can create an unsafe condition which to lead to a fire safety hazard injury or death Figure 5 Straight through ceiling and roof installation for 4 inch B Vent installa...

Страница 9: ...loor hearth Min 64 exterior exhaust M Power Vent exhaust Motor 5 Wiring Diagram with VANOX PV1500 Powervent Figure 7a Powervent with VANOX PV1500 NOTES 1 All flex venting components must be insulated...

Страница 10: ...ng a match or something that will produce smoke place it up to the opening of the draft hood and verify that the flame or smoke is being drawn into the draft hood If the flame or smoke is blown away f...

Страница 11: ...ace sur rounds to select and apply a quality Alkyd sealer prior to the applying of latex paints This is to prevent leaching of water from evaporation and causing a brownish staining effect to paint ov...

Страница 12: ...minimum height and width require ments for a combustible mantel AVERTISSEMENT Objets combustibles ne doivent pas tre plac s sur un manteau non combustible moins que le linteau incombustible est confo...

Страница 13: ...directly into a properly grounded three e pronged receptacle Do not cut or remove the ground ing prong from the plug AVERTISSEMENT lectriques instructions de mise la terre Cet appareil est quip d un t...

Страница 14: ...e glass will void all product warran ties Do not strike or abuse glass Care must be taken to avoid breakage of glass Do not operate this fireplace without the glass front or with broken glass AVERTISS...

Страница 15: ...of Screen Removing the door Safety Screen The VL36BN door is removed in a few simple steps Follow these instructions below to remove the Horizontal access panel unlatch the door buckles and remove the...

Страница 16: ...ngs are accessible for test gauge connection both on the inlet and outlet of the gas valve 7 Turn the gas supply ON and check for leaks DO NOT USE OPEN FLAME FOR THIS PURPOSE Use an approved leak test...

Страница 17: ...Section 8 Operation Lighting Instructions SIT Millivolt Valve Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 17...

Страница 18: ...Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 18 SIT Millivolts Valve...

Страница 19: ...SIT IPI Valve Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 19...

Страница 20: ...Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 20...

Страница 21: ...ative trim from the glass tray the glass media and the glass burner tray itself The burner glass tray is removed by removing all 11 bolts from around the burner 3 Undo the gas line and the burner tray...

Страница 22: ...ith glass media of choice Please install as shown below Figure 36 Firebox without media installed GND FSC Fan Switch HN Fan 115VAC 60Hz Important Notice After the fan is installed and the wiring harne...

Страница 23: ...t activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the result of burning of protective coatings on new metal 1 Glass must be cleaned pe...

Страница 24: ...ing or servicing leak test with a soap solution with main burner on Coat pipe and tubing joints gasket etc with soap solution Bubbles indicate leaks Tighten any areas where the bubbles appear until th...

Страница 25: ...2 The Vanox Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause dam...

Страница 26: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 26...

Страница 27: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 27...

Страница 28: ...Vanox Fireplaces Inc Port Coquitlam BC VANOX Fireplace Inc P r i n t e d i n C a n a d a Part No VL36BN Man 072414...

Отзывы: