                                                    TSR-2 Remote Control

TruSine 4.5 kW Inverter

Page 14

Owners Manual

MONITOR Menu:

20

AUTOSCAN 

System status display

Go to Step 30

21

MANUAL SCAN

System status display

Go to Step 40

AUTOSCAN Menu:

30

Press ESC to quit.

Go to 31

31

Inverter/Charger/System Displays inverter status message

Go to 32

SYSTEM STATUS

32

APM Limit

Displays APM setpoint

Go to 33

XX Amps AC

33

Aux AC Input

Displays if Aux AC Input is within voltage

Go to 34

             ERROR

and frequency tolerance

34

System AC Volts

Displays Aux AC input volts or 

Go to 35

      XXX VAC

inverter AC output volts

35

System AC Amps

Displays Aux AC input amps or

Go to 36

   XXX Amps AC

inverter AC output amps

36

Battery Volts

Displays battery voltage

Go to 37

   XX.XX  VDC

37

Battery Status

Displays if battery is within operating range

Go to 38

   GOOD

(within high and low battery setpoints)

38

Batt Temperature

Displays battery temperature if optional 

Go to 31

    XXX º C

battery temperature sensor is installed

MANUAL SCAN Menu:

40

Inverter/Charger/System Displays inverter status message

Go to 41

SYSTEM OFF

41

APM Limit

Displays APM setpoint

Go to 42

XX Amps AC   

42

Aux AC Input

Displays if Aux AC Input is within voltage

Go to 43

ERROR

and frequency tolerance

43

System AC Volts

Displays Aux AC input volts or

Go to 44

     XXX VAC

inverter AC output volts

44

System AC Amps

Displays Aux AC input amps or

Go to 45

  XXX Amps AC

inverter AC output amps

45

Battery Volts

Displays battery voltage

Go to 46

   XX.XX  VDC

46

Battery Status

Displays if battery is within operating range

Go to 47

   GOOD

(between high and low battery setpoints)

47

Batt Temperature

Displays battery temperature if optional

Go to 40

Содержание TruSine 4500 TSC24-4500

Страница 1: ...Owner s Manual TruSine 4 5 kW Inverter Page 1 Owner s Manual TruSine 4500 4 5 kW Inverter Charger System 4 5 kW Power Inverter Models TSC24 4500 TSC24 4500D Owner s Manual D98771 Rev B...

Страница 2: ...TruSine 4500 TruSine 4 5 kW Inverter Page 2 Owners Manual Notes...

Страница 3: ...ING 18 4 3 SYSTEM ON INDICATOR 18 4 4 BATTERY TEMPERATURE SENSOR PORT 18 4 5 V NET PORT TSR 2 REMOTE CONTROL PORT 18 4 6 SERIAL INTERFACE PORT 18 4 7 INVERTER OUTPUT CIRCUIT BREAKER 18 4 8 SYSTEM ON O...

Страница 4: ...TruSine Remote Control Panel operator s interface which utilizes a high speed data highway to connect one or more TSR 2 units to the inverter INVERTER CHARGER MICROPROCESSOR CONTROLLER AUTOMATIC AC TR...

Страница 5: ...a variety of protection interlocks system fault detection reporting recovery storage of system data parameters and high speed data communications to the optional TSR 2 Remote Control Panel System pro...

Страница 6: ...15 watts 62 8 63 1 30 watts 72 6 71 2 60 watts 62 6 75 2 100 watts 72 3 71 7 400 watts 88 5 88 3 1100 watts 91 3 92 2 1500 watts 90 6 90 7 2000 watts 89 4 89 50 3200 watts 86 2 86 7 3900 watts 83 7 8...

Страница 7: ...uto restart will restart the inverter after battery voltage rises above the Low Battery Warning setpoint High Battery The inverter will shut OFF if battery voltage rises above the High Battery setpoin...

Страница 8: ...switch to DISABLED at the end of the Equalize Charge Cycle During the Equalize Cycle the battery is charged at the Absorption Charge Amps setpoint and the Equalize Voltage setpoint The Equalize Charg...

Страница 9: ...AC Input frequency and battery voltage In the normal mode of operation Solar Mode OFF the Automatic Transfer Switch will automatically accept in tolerance Aux AC input power whenever it is available w...

Страница 10: ...taller to adjust the system operation factory setpoints and allows the user to monitor and control in detail the TruSine Inverter Charger operation The TSR 2 connects to the inverter at the V NET Port...

Страница 11: ...OFF Battery Temp Coefficient Same Same 0 25 5 4 0 mV C Cell Battery Charger Battery Temp Shut Down Same Same 0 255 50 C Gen Start Mode Same Same ON OFF ON Gen Start Batt Voltage Same Same 20 0 25 0 22...

Страница 12: ...rom the Control Menu INVERTER ENABLED disabled MENU ESC PUSH TO SCROLL UP PUSH TO ENABLE PUSH TO GO BACK ONE MENU LEVEL PUSH TO RETURN TO MAIN MENU PUSH TO DISABLE PUSH TO SCROLL DOWN SHOWN ENABLED Ad...

Страница 13: ...p Initial Display Push any button to enter main menu TSR 2 A88769 A MAIN MENU Ref Step Display Function Action 1 BSCONTROL Selects the BASIC CONTROL submenu Go to Step 10 2 MONITOR Selects the MONITOR...

Страница 14: ...ttery Status Displays if battery is within operating range Go to 38 GOOD within high and low battery setpoints 38 Batt Temperature Displays battery temperature if optional Go to 31 XXX C battery tempe...

Страница 15: ...left upper right Step 61 if not Go to Step 6 61 ADVANCED CONTROL Selects ADVANCED CONTROL submenu Go to Step 70 62 COMMUNICATIONS Selects the COMMUNICATIONS submenu Go to Step 90 ADVANCED CONTROL Men...

Страница 16: ...point 85 Gen Start Mode Allows Gen Start to operate automatically ON Go to Step 86 on OFF or turns Gen Start OFF 86 GenStart Volts Adjusts battery voltage setpoint at which the Go to Step 87 XX XX VDC...

Страница 17: ...wn setpoint will shut down system 3 Battery Low Battery voltage is below Low Battery Warning setpoint and soon will reach Low Battery Shutdown setpoint 4 Current Limit Inverter AC output amps are at t...

Страница 18: ...180 degrees out of phase and cannot be tied together The unit may be damaged if the AC input power is not 180 degrees out of phase Examples of unacceptable power are two phases from a three phase gen...

Страница 19: ...es 102 mm should be maintained on all sides of the unit WARNING Risk of fire or explosion The inverter must not be mounted in fuel storage areas battery compartments or other areas hazardous locations...

Страница 20: ...ion The DC input terminals are located in the field wiring compartment located at the front right side of the unit and accessed from the top The connections are compression terminals which require a s...

Страница 21: ...sed for the AC output The AC transfer switch is rated 30 amps at 120 volts Use input wire up to 6 AWG sized to suit the AC input source The AC output wire should be the same size as the AC input wire...

Страница 22: ...try on the right side Step 2 Route the data cable from the remote panel mounting area to the inverter Step 3 Plug the data cable into the RJ 11 modular jack labeled V NET on the front of the inverter...

Страница 23: ...peak voltage and smooth voltage transitions no square wave components Such inverters are the most costly of the three inverter types because they contain additional electronics to produce the require...

Страница 24: ...nstructions from a specific battery or other equipment manufacturer Vanner recommends that those manufacturer s recommendations be followed 6 3 DC Power Consumption An inverter takes in DC power and p...

Страница 25: ...cling ability RC is a rating given to cranking batteries to provide an idea of how long a vehicle could be driven if the vehicle charging system were to fail The most important and probably least unde...

Страница 26: ...4 the DC current draw from the battery does not exceed 1 3 the C rate for any length of time Follow the steps listed below to find the AH capacity required for your application Step 1 Make a list of...

Страница 27: ...Battery Charging Guidelines CAUTION The following information on battery charger setup adjustments should be used as guidelines only Vanner strongly recommends that you contact the manufacturer of you...

Страница 28: ...General Information TruSine 4 5 kW Inverter Page 28 Owners Manual Mode See TSR 2 Remote Control Panel operation...

Страница 29: ...re no other warranties that extend beyond those described on the face of this warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitations may not apply...

Страница 30: ...W Inverter Page 30 Owners Manual Vanner Power Group 4282 Reynolds Drive Hilliard Ohio 43026 1 800 AC POWER 1 800 227 6937 Tel 614 771 2718 Fax 614 771 4904 www vanner com e mail pwrsales vanner com Ma...

Отзывы: