VANNER
Incorporated
OWNER’S MANUAL
Vanner High Voltage DC-
DC Converter OWNER’S MANUAL
14
Wire Size and Temperature Rating
Cables connecting the HBA
to the 24V batteries must be sufficiently sized to prevent unwanted voltage
drop. The temperature rating of the wire should be a minimum of 90ºC.
Vanner recommends the following wire and fuse sizes for the 250A and 300A HBA's. To protect the
positive cable, it shall be fused as close to the 24V battery as practical.
HBA Low Voltage Output Wire and Fuse Size Chart
Wire
Size
AWG
Ring Terminal
Panduit
Fuse F3
#4/0
*LCD4_0-56000-CUST
400 amp
* The Panduit part number listed is recommended, not required, by Vanner. Equivalent substitutes may
be used. Contact Vanner engineering for a drawing of the Panduit ring terminal.
The recommended terminal is a right angle lug that enables the installer to route the 4/0 cables along the
side of the HBA. Factory installed tie wrap bases are present on the side of the HBA for strain relief.
Crimp the ring terminals using
Panduit CT-930
manual/hydraulic crimping tool.
Use
Panduit
die
CD-920-4/0
die. (Purple P54).