2.  Plug one micromotor into the receptacle on the back of the dust collector. If the dust collector comes 

on, the sensitivity is set too high for your micromotor; we will adjust it in a moment. If the  dust collec

-

tor did not start when first plugged in; start the micromotor now. If the dust collector starts, then the 

sensitivity is set correctly. The dust collector will continue to run for about 5 to 10 seconds after you 

stop using the micromotor.

3.  If the sensitivity is not set correctly, it can be adjusted by the screw located on the front of the unit 

to the left of the switches. There are two adjustment screws. Only adjust the one on the right.  To 

increase the sensitivity, gently turn the screw counter-clockwise (to the left). If your dust collector did 

not start when you started the micromotor, then increase the sensitivity by gently turning the screw 

slightly counter-clockwise waiting two seconds after each adjustment. Try the micromotor again. If the 

dust collector does not start, then gently increase sensitivity a little more. Repeat this process until the 

dust collector starts when the micromotor is running. If the dust collector starts but does not turn off 

even when the micromotor is stopped, you may have to decrease the sensitivity slightly.

4.  If after following these steps, the unit does not operate properly, please contact Vaniman as there may 

be addition adjustments or steps that can be made to attain the results you require.

NSK Ultimate XL-K and/or Z500 Series Handpiece Users
From the NSK Ultimate XL-K and Z500 Users manual:

“Vacuum-coupled Mode"
On some dental tables with vacuum dust collector, the motor may be used while being coupled with a 

dust collector.

When such a dust collector is used, power consumption of the Ultimate XL-K/Z500 can be regulated so 

that the vacuum coupled function can work. If you need coupling with a vacuum dust collector, select 

the mode as follows:

How to select the mode

While pressing Forward/Reverse Selector Switch (button), turn on the Power Switch, and the mode can 

be selected. A long beep indicates vacuum-coupled mode and 2 short beeps indicate non-coupled mode. 

Each time the switch selection is made, the mode changes between vacuum-coupled mode and non-

coupled mode.

MAINTENANCE

1.  Cleaning the Filter

 - When a noticeable drop in suction occurs with the StoneVac II, it is time to clean 

the filter.  To use the self-cleaning feature of the StoneVac II, push and hold the Power switch in the 

CLEAN

 position for several seconds. Optimum cleaning takes place within 5 seconds. For best re

-

sults, wait an additional 5-7 seconds with the Power switch in the 

OFF

 or center position, this allows 

the dust cleaned from the filter to fall into the dust bin before turning the unit on again.

2.  Emptying the Dust Bin 

- Depending on usage, the Dust Bin will need to be emptied at different inter

-

vals. Check the level of dust in the bin by lifting and turning the latches on the unit door panel.  Open 

and observe the dust level. To empty, set the panel aside and slide the Dust Bin from the unit; pull the 

retaining band off from around the Dust Bin ledge and gather the sides of the plastic bag together. Re

-

place the bag with a Vaniman replacement and place the bag into the Dust Bin, folding the open end 

of the bag over the Dust Bin edges, and putting the retaining band around the bag edges as before. 

Then slide the Dust Bin back into the unit. Replacement dust bin bags 