ACCUMULATOR HOSE CONNECTION:
1. The Inlet and Outlet of the Accumulator are designed to recieve Vaniman's 2.5" hose or 1.5" hose
with Vaniman's reducing adapter.
2. The Accumulator is installed between the workstation and the Dust Collector. Connect the hose from
the Dust Collector to the
Outlet
on top of the Accumulator by gently sliding the hose end into the
Accumulator until snug. The hose collecting the debris should connect to the
Inlet
(horizontal arm)
of the Accumulator by gently sliding the hose end into the Accumulator until snug.
ACCUMULATOR OPERATION:
3. After making your hose connections and before turning your Dust Collector on, ensure the two Toggle
Latches on the Collection Cup are snapped in place to secure the Collection Cup to the bottom of
the Accumulator.
4. To remove the cup, turn the Dust Collector off and gently tap the sides of the Accumulator to knock
down dust from the Accumulator walls into the cup. Hold the Collection Cup with one hand on each
side directly below the toggle latches, and with your index fingers flip the Toggle Latches upward
then swing the Wire Bales outward. Carefully lower the Collection Cup and empty the contents.
Replace the cup onto the bottom rim of the Accumulator, swing the wire bales over the bottom rim
of the Accumulator, and snap the Toggle Latches down to secure the cup in place.
NOTE:
While Collection Cup is removed from the Accumulator, inspect the gasket on the bottom of the
Accumulator body where the Collection Cup meets it. If damaged or in need of replacement, contact
Vaniman to order a replacement. Without this gasket, the collected material could escape from the
collection system.
5. Turn the vacuum system on and use as you normally would. As the collector pot fills with dust, you can see
the material through the translucent walls of the Collection Cup. It is best to empty the Collection Cup daily
or when it is half full.