Figure 15 - Gas Connection (Variable 

Manually-Controlled Models Only)

 Tee 

Pipe  Cap

 Joint  Nipple

3" Minimum

PROPANE/LP

From External 
Regulator (11" W.C.** 
to 14" W.C. Pressure)

NATURAL

From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)

Equipment Shutoff Valve 
With 1/8" NPT Tap*

Approved Flexible 
Gas Hose (if allowed 
by local codes)

Sediment Trap

Gas 
Regulator

INSTALLATION

Continued

Installation must include an equipment shutoff 
valve, union and plugged 1/8" NPT tap. Locate 
NPT tap within reach for test gauge hook up. 
NPT tap must be upstream from heater (see 
Figure 15 or 16, depending on your model).

IMPORTANT:

 Install equipment shutoff valve 

in an accessible location. The equipment 
shutoff valve is for turning on or shutting off 
the gas to the appliance.
Check your building codes for any special 
requirements for locating equipment shutoff 
valve to fireplaces.
Apply pipe joint sealant lightly to male NPT 
threads. This will prevent excess sealant from 
going into pipe. Excess sealant in pipe could 
result in clogged heater valves.

 WARNING: Use pipe joint 

sealant that is resistant to liquid 
petroleum (LP) gas.

We recommend that you install a sediment trap 
in supply line as shown in Figure 15 or Figure 
16, page 15, depending on your model. Lo-
cate sediment trap where it is within reach 
for cleaning. Install in piping system between 
fuel supply and heater. Locate sediment 
trap where trapped matter is not likely to 
freeze. A sediment trap traps moisture and 
contaminants. This keeps them from going 
into heater controls. If sediment trap is not 
installed or is installed wrong, heater may 
not run properly.

 CAUTION: Avoid damage to 

regulator. Hold gas regulator 
with wrench when connecting 
it to gas piping and/or fittings 
(Variable Manually-Controlled 
Models Only).

 CAUTION: Avoid damage 

to gas control. Hold gas fitting 
with wrench when connecting 
it to gas piping and/or fittings 
(Remote-Ready Models Only).

* Purchase the optional equipment shutoff 
valve from your dealer.
** Minimum inlet pressure for purpose of input 
adjustment. 

Figure 16 - Gas Connection (Remote-

Ready Models Only)

Gas 
Control 

3” Minimum

Equipment Shutoff 
Valve With 1/8" 
NPT Tap*

Approved 
Flexible 
Gas Hose (if 
allowed by 
local codes)

PROPANE/LP

From External 
Regulator (11" 
W.C.** to 14" W.C. 
Pressure)

NATURAL

From Gas Meter

(5" W.C.** to
           10.5" W.C.
            Pressure)

 Cap 

Pipe  Tee

   Nipple 

Joint

Sediment Trap

Содержание VYD18NRB

Страница 1: ...hone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the ga...

Страница 2: ...llation only in a solid fuel burn ing masonry or UL127 factory built fireplace or in a listed ventless firebox enclosure It is design cer tifiedfortheseinstallations in accordance with ANSI Z21 11 2 E...

Страница 3: ...p this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exch...

Страница 4: ...ure there are no obstructions across openings of fireplace 8 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 24 9 Before using furniture polish wax carpet clea...

Страница 5: ...purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts LOCAL CODES Install and use heater...

Страница 6: ...is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fire...

Страница 7: ...0 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace __________ Btu Hr Gas water heater __________ Btu Hr Gas furnace ________...

Страница 8: ...ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces incl...

Страница 9: ...to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as but not limited to tobacco smoke aromatic candles cleaning flu ids oilorkerosenelamps et...

Страница 10: ...mple Minimum Noncombustible Material Clearances If Not Using Mantel Note If using a mantel proceed to If Using Mantel page 11 If not using a mantel follow the information on this page You must have no...

Страница 11: ...and 7 for minimum clearances IMPORTANT If you cannot meet these mini mum clearances you must operate heater with chimney flue damper open Go to Install ing Damper Clamp Accessory for Vented Operation...

Страница 12: ...ucted of noncombustible material For Massachusetts Residents Only Instal lation of this vented gas log set in the Com monwealth of Massachusetts requires the damper be permanently removed or welded in...

Страница 13: ...Remote Ready models connect approved flexible gas hose to gas control fitting in heater see Figure 12 IMPORTANT Hold gas regulator with wrench when connecting flexible gas hose Variable Manually Contr...

Страница 14: ...lant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench A equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge...

Страница 15: ...t that is resistant to liquid petroleum LP gas We recommend that you install a sediment trap in supply line as shown in Figure 15 or Figure 16 page 15 depending on your model Lo cate sediment trap whe...

Страница 16: ...alve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a le...

Страница 17: ...grams or failure to use only parts specifically approved with this heater may result in property damage or personal injury CAUTION After installa tion and periodically thereafter check to ensure that...

Страница 18: ...RE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be...

Страница 19: ...repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 20 Figure 23 Control Knob and Ignitor Button Location Control Knob Ignitor Button OPERATION Continu...

Страница 20: ...of the HI heat setting but will find the heat output excessive You can open the chimney damper if you have one fully or partially to release some of the heat Thermocouple Ignitor Electrode Pilot Burn...

Страница 21: ...ION Continued REMOTE READY MODELS Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match...

Страница 22: ...e REMOTE or ON position when the pilot is not lit This will drain the battery ON OFF SERIES MODEL HRC100 Hold the control button on the hand held remote until burner turns on Hold the control button a...

Страница 23: ...ton Locks System to Prevent Accidental Ignition Turns Burners On or Off Increases or Decreases Room Temperature in AUTO Mode Digital Display Shows Temperature and Settings the room temperature If the...

Страница 24: ...ore each use Have heaterinspectedyearlybyaquali fied service person Heater may needmorefrequentcleaningdue to excessive lint from carpeting pet hair bedding material etc WARNING Failure to keep the pr...

Страница 25: ...to Installing Logs page 17 to properly replace logs Replace log s if broken or chipped dime sized or larger MAIN BURNER Periodically inspect all burner flame holes with the heater running All slotted...

Страница 26: ...in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing...

Страница 27: ...ODS pilot lights keep control knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natur...

Страница 28: ...LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Cleaning and Maintenance page 24 or replace burner orifice 1 Turn heater off when us ing furniture...

Страница 29: ...eaning and Maintenance page 24 1 Locate and correct all leaks see Checking Gas Con nections page 16 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all l...

Страница 30: ...ximum 14 w c Minimum 11 w c VYD18NRB Rating 21 000 30 000 Btu hr Gas Type Natural Ignition Piezo Manifold Pressure 3 5 w c Inlet Supply Pressure inches of water Maximum 10 5 w c Minimum 5 w c VYD24PRB...

Страница 31: ...T SWITCH GWMT1 For all Remote Ready Models The desired comfort setting can be selected on the wall thermostat and the log heater will auto matically cycle from pilot to the heat setting selected WALL...

Страница 32: ...products com 113093 01J 32 PARTS VARIABLE MANUALLY CONTROLLED BASE ASSEMBLY FOR FLAME MAX VINTAGE OAK LOG MODELS VYS18PB VYS18NB VYS24PB AND VYS24NB 4 1 12 3 10 11 3 7 3 5 8 9 15 14 16 19 2 18 13 19 1...

Страница 33: ...Gas 1 111331 04 Outlet Burner Natural Gas 1 9 102798 01 Inlet Tube 1 10 099056 21 Burner Orifice Injector Propane LP Gas 1 099056 20 Burner Orifice Injector Natural Gas 1 099056 19 Burner Orifice Inje...

Страница 34: ...REMOTE READY BASE ASSEMBLY FOR FLAME MAX GOLDEN OAK LOG MODELS VYD18PRB VYD18NRB VYD24PRB VYD24NRB VYD30PRB AND VYD30NRB Parts 23 and 24 Natural Gas Only 4 13 14 22 13 18 7 6 9 12 5 16 15 17 3 11 2 1...

Страница 35: ...jector LP 1 099056 16 Burner Orifice Injector NG 1 099056 37 Burner Orifice Injector LP 1 8 14579 Switch 1 9 102980 01 Burner 1 102772 01 Burner 1 10 099387 15 Pilot Tube NG 1 099387 13 Pilot Tube LP...

Страница 36: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic m...

Отзывы: