background image

17

105706

OWNER’S MANUAL

INSTALLATION

Continued

Installing 9-Volt Alkaline Battery in
Hand-Held Remote Control Unit

1.

Remove battery cover on back of re-
mote control unit.

 2. Attach terminal wires to the battery

(not included). Place battery into the
battery housing.

3.

Replace battery cover onto remote con-
trol unit.

Figure 37 - Installing Battery in Hand-
Held Remote Control Unit

Battery
Cover

9-Volt
Battery

Terminal
Wires

Remote
Control Unit

Battery
Housing

Continued

GAS LINE HOOK-UP

Figure 38 - Typical Exterior Wall Gas
Shut-Off Installation

 WARNING: Gas line hookup

should be done by your gas sup-
plier or a qualified service person.

 WARNING: Before you pro-

ceed, make sure your gas supply
is OFF.

A manual shut-off valve has been  included
in the appliance’s gas supply system. You
may consider installing an extra gas shut-off
valve outside the appliance’s enclosure
(check with local codes) where it can be
accessed more conveniently with a key
through a wall as shown in Figure 38.

Route a 1/2” NPT black iron gas line to-
wards the appliance coming in from the left.
It is recommended to route the pipe between
the stand of the firebox and the surround of
the fireplace (see Figure 39).

IMPORTANT:

 The appliance and its indi-

vidual shut-off valve must be disconnected
from the gas supply piping system during
any pressure testing of that system at test

Key

Extension

Shut-Off Valve

 CAUTION: Compounds used

on threaded joints of gas piping
shall be resistant to the action of
Liquefied Petroleum (LP or pro-
pane), and should be applied
lightly to ensure excess sealant
does not enter the gas line.

 CAUTION: Do not kink flex-

ible gas line.

pressures in excess of 1/2 psig. (3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its indi-
vidual manual shut-off valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig. (3.5 kPa).

 WARNING: All gas piping

and connections must be tested
for leaks after the installation is
completed.

After ensuring that the gas valve
is open, apply a soap and water
solution to all connections and
joints. If bubbles appear, leaks
can be detected and corrected.

Do not use an open flame for leak
testing and do not operate any
appliance if a leak is detected.

Bac

k W

all

Of Appliance

Incoming 1/2"
Gas Line
Permitted by
Local Codes

Sediment Trap (Not Supplied)

Figure 39 - Sediment Trap

 WARNING: Improper installa-

tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Refer
to this manual. For assistance or
additional information, consult a
qualified installer, service
agency, or gas supplier.

GAS RATING

TYPE OF GAS

NATURAL

PROPANE/LP

Max. Input Rating:

30,000 Btu/hr

28,000 Btu/hr

Orifice Size (0-4,500 Ft.):

7/64"

#52

Minimum Input Rating:

21,000 Btu/hr

20,000 Btu/hr

   (When the Valve is in
   the LOW Position)

* Maximum Output Rating:

21,000 Btu/hr

20,000 Btu/hr

Manifold Pressure:

3.5 in. WC

10.0 in. WC

**Minimum Supply Pressure:

4.5 in. WC

11.0 in. WC

**Maximum Supply Pressure:

10.5 in. WC

13.0 in. WC

1.

Install a sediment trap between the in-
coming gas line and the gas control
valve (see Figure 39). The sediment
trap should extend down the center of
the pipe. Refer to your local codes.

2.

Prepare incoming gas line and check
with local codes regarding the use of
teflon tape. Complete your gas line in-

stallation by connecting incoming gas
line with flexible gas line.  Secure
tightly with a wrench, but Do NOT
Overtighten.

* 70% Efficiency (flue loss calculation).
** For the purpose of input adjustment.

Содержание VDVF36PN

Страница 1: ...s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier SAVE THIS BOOK This...

Страница 2: ...sions Back of Surround Back of Surround Figure 2 VDVF36STN STP See Thru Dimensions Left Side Surround Right Side Surround Rating Plate Location Left Side Surround Right Side Surround GLOSSARY OF TERMS...

Страница 3: ...han the type of gas approved for use in this gas appliance NOTICE Check local building codes for area requirements be fore installing this appliance This appliance when installed must be elec trically...

Страница 4: ...UTION Do not block re quired air spaces with insula tion or any other material Do not obstruct the effective opening of the appliance with any type of facing material MANTEL CLEARANCES Woodwork such a...

Страница 5: ...maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding Install horizontal venting with a 1 4 rise for every 12 of run toward the ter mination You may paint the vent terminal...

Страница 6: ...ve paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum...

Страница 7: ...t the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizo...

Страница 8: ...s to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide s...

Страница 9: ...utside edge of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is...

Страница 10: ...rtical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting FGFVK Vent Kit Shown Horizontal Termination Configurations Figures 21 through 23 show different con figurat...

Страница 11: ...90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 4 max 6 min 8 max 7 min 10 max 8 min 15 max 20 max 20 max Figure 23 Horizontal Termination Configuration for Rigid Venting Using Two 90 Elbows w...

Страница 12: ...nces air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do not pack air spaces with insulation Also note maxi mum vertical rise of the venting sys tem an...

Страница 13: ...ort box vertically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corne...

Страница 14: ...guration With No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 ma...

Страница 15: ...12 Firestop Support Roof Flashing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial...

Страница 16: ...erly connected to a standard 120 VAC power source Refer to Wiring Diagram on page 23 An outlet box with two receptacles has been supplied for your convenience located on the lower left side of the app...

Страница 17: ...sig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its indi vidual manual shut off valve during any pressure testing of the gas supply piping system at test pressu...

Страница 18: ...is section is intended as a guide for qualified service technicians installing gas to the appliance CAUTION Do not connect appliance before pressure test ing gas piping Damage to the gas valve may res...

Страница 19: ...roofed is not considered noncombustible Left Right Back Front Left Front Right Back B B A A Figure 44 Installing Logs A Top View Figure45 InstallingLogs B TopView PILOT ASSEMBLY ADJUSTMENT The pilot a...

Страница 20: ...proper safety gloves to re move the broken glass door Dis card safely A glass door kit can be ordered through your local distributor Do not substitute other material for the glass WARNING Children an...

Страница 21: ...all electrical power to the appliance 4 Open control access panel 5 Push in gas control knob slightly and turn clockwise to OFF 6 Wait five 5 minutes to clear out any gas Then smell for gas including...

Страница 22: ...ineered to take an air temperature sample ev ery 5 5 minutes in the auto mode It will not respond immediately to the temperature setting being turned up or down IMPORTANT The hand held re mote control...

Страница 23: ...ilot will not stay lit burner will produce flames and soot fireplace will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier WIRI...

Страница 24: ...ing to light the fireplace 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician rep...

Страница 25: ...6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut i...

Страница 26: ...rner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Clean burner or replace burner orifice 1 Adjust the log set so that the flame does not excessively impinge...

Страница 27: ...ent cap installation 1 Gas leak See Warning statement above 2 Control valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame...

Страница 28: ...KIT 105742 01 22180 Wall Switch 105902 01 14112 Cover Plate 105903 01 14113 Wallswitch coverplate andmillivoltwires are supplied with the appliance If wires need replacing use proper gauge Millivolt...

Страница 29: ...105890 02 25238 REFRACTORY PIECES Front Bottom 105886 01 25854 Left Right Bottom 105887 01 25856 Rear 105888 01 25855 BURNER ASSEMBLY 105885 01 27243 REPLACEMENT PARTS Continued Front Bottom Left Rig...

Страница 30: ...e the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES A...