DIRECT-VENT GAS FIREPLACE HEATER

VDVF36P and VDVF36ST Series

®

Figure 33 - Wall Switch Wiring Diagram

OPTIONAL WIRELESS HAND-
HELD REMOTE CONTROL
(GHRC(T) SERIES)
INSTALLATION

Note:

 If using an optional wireless hand-

held remote control, the wall switch is no
longer operational.

Figure 35 - Installing Remote Receiver
(Shown from Rear of Mounting Bracket)

Figure 36 - Installing Battery in Receiver

INSTALLATION

 WARNING: Do not wire re-

mote wall switch to main power
supply (Standard 120v household
current).

WALL SWITCH
INSTALLATION

Since the VDVF36 series models use a
valve that operates on millivolt current gen-
erated by the pilot, a wall switch may be
used to activate the gas control valve with-
out the use of normal household electricity.

1.

To remove the louvers, simultaneously
pull both top end spring latches towards
the center of the appliance until they
are disengaged from locating holes.
Repeat for bottom end spring latches
and pull outward. Reverse the proce-
dure to install louvers back onto the
appliance (see Figure 32).

2.

Connect the 18 ga. wires from wall
switch to the gas control valve and
microswitch, as  shown in Figure 33.

OFF

P

IL

O

T

ON

L

O

H

I

PI

LOT

E

A

16AI

7

TPTH        

TP         

TH

Wall Switch
(Supplied)

Route Millivolt Wires (Supplied)
Through Gas Line Conduit Sleeve

To
Thermopile

(Back View)

ELECTRICAL HOOKUP FOR
BLOWER ACCESSORY

Before blower accessory can be operated, it
must be properly connected to a standard
120 VAC power source. Refer to Wiring
Diagram
 on page 23.

An outlet box with two receptacles has been
supplied for your convenience, located on
the lower left side of the appliance (see
Figure 34). An optional remote control may
be installed at any time.

Figure 34 - Connecting Blower Accessory
to Power Supply

For Optional
Fan Kit

From Blower
Assembly

Note:

 If any of the original wire supplied must be replaced, use type 18 AWG-105 degree

C (25 feet length MAXIMUM) or equivalent.

 CAUTION: Due to high tem-

peratures, make sure no wires
are touching the bottom of the
firebox.

Figure 32 - Removing Louver

Glass

Locating
Holes

Spring
Latch

NOTICE: Only use alkaline bat-
teries (not included).

Installing Receiver

1.

Remove access panel from lower front
face of firebox. Lift straight up on ac-
cess panel until it stops. Pull bottom of
access panel forward, then down.

2.

Disconnect wall switch wires from TH
and TPTH terminals on control valve
(see Figure 33).

3.

Install remote receiver unit onto mount-
ing bracket using the two plastic mount-
ing clips (see Figure 35).

4.

Connect wires to control valve. Con-
nect white wire to terminal TH. Con-
nect red wire to terminal TPTH.

5.

Locate the battery clip mounted on the
back of the receiver (see Figure 36).

6.

Slide 9-volt battery (not included)
through the clip.

7.

Attach the terminal wires to the battery
(see Figure 36).

8.

Replace access panel. Place top of ac-
cess panel into opening and slide up.
Push bottom of access panel in and
slide down to install.

Battery Clip

9-Volt Battery

Receiver

Terminal
Wires

Receiver

Mounting
Bracket

Plastic
Mounting
Clips

Содержание VDVF36PN

Страница 1: ...s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier SAVE THIS BOOK This...

Страница 2: ...sions Back of Surround Back of Surround Figure 2 VDVF36STN STP See Thru Dimensions Left Side Surround Right Side Surround Rating Plate Location Left Side Surround Right Side Surround GLOSSARY OF TERMS...

Страница 3: ...han the type of gas approved for use in this gas appliance NOTICE Check local building codes for area requirements be fore installing this appliance This appliance when installed must be elec trically...

Страница 4: ...UTION Do not block re quired air spaces with insula tion or any other material Do not obstruct the effective opening of the appliance with any type of facing material MANTEL CLEARANCES Woodwork such a...

Страница 5: ...maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding Install horizontal venting with a 1 4 rise for every 12 of run toward the ter mination You may paint the vent terminal...

Страница 6: ...ve paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum...

Страница 7: ...t the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizo...

Страница 8: ...s to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide s...

Страница 9: ...utside edge of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is...

Страница 10: ...rtical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting FGFVK Vent Kit Shown Horizontal Termination Configurations Figures 21 through 23 show different con figurat...

Страница 11: ...90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 4 max 6 min 8 max 7 min 10 max 8 min 15 max 20 max 20 max Figure 23 Horizontal Termination Configuration for Rigid Venting Using Two 90 Elbows w...

Страница 12: ...nces air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do not pack air spaces with insulation Also note maxi mum vertical rise of the venting sys tem an...

Страница 13: ...ort box vertically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corne...

Страница 14: ...guration With No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 ma...

Страница 15: ...12 Firestop Support Roof Flashing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial...

Страница 16: ...erly connected to a standard 120 VAC power source Refer to Wiring Diagram on page 23 An outlet box with two receptacles has been supplied for your convenience located on the lower left side of the app...

Страница 17: ...sig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its indi vidual manual shut off valve during any pressure testing of the gas supply piping system at test pressu...

Страница 18: ...is section is intended as a guide for qualified service technicians installing gas to the appliance CAUTION Do not connect appliance before pressure test ing gas piping Damage to the gas valve may res...

Страница 19: ...roofed is not considered noncombustible Left Right Back Front Left Front Right Back B B A A Figure 44 Installing Logs A Top View Figure45 InstallingLogs B TopView PILOT ASSEMBLY ADJUSTMENT The pilot a...

Страница 20: ...proper safety gloves to re move the broken glass door Dis card safely A glass door kit can be ordered through your local distributor Do not substitute other material for the glass WARNING Children an...

Страница 21: ...all electrical power to the appliance 4 Open control access panel 5 Push in gas control knob slightly and turn clockwise to OFF 6 Wait five 5 minutes to clear out any gas Then smell for gas including...

Страница 22: ...ineered to take an air temperature sample ev ery 5 5 minutes in the auto mode It will not respond immediately to the temperature setting being turned up or down IMPORTANT The hand held re mote control...

Страница 23: ...ilot will not stay lit burner will produce flames and soot fireplace will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier WIRI...

Страница 24: ...ing to light the fireplace 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician rep...

Страница 25: ...6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut i...

Страница 26: ...rner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Clean burner or replace burner orifice 1 Adjust the log set so that the flame does not excessively impinge...

Страница 27: ...ent cap installation 1 Gas leak See Warning statement above 2 Control valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame...

Страница 28: ...KIT 105742 01 22180 Wall Switch 105902 01 14112 Cover Plate 105903 01 14113 Wallswitch coverplate andmillivoltwires are supplied with the appliance If wires need replacing use proper gauge Millivolt...

Страница 29: ...105890 02 25238 REFRACTORY PIECES Front Bottom 105886 01 25854 Left Right Bottom 105887 01 25856 Rear 105888 01 25855 BURNER ASSEMBLY 105885 01 27243 REPLACEMENT PARTS Continued Front Bottom Left Rig...

Страница 30: ...e the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES A...

Отзывы: