1.

STOP! Read the safety information
above.

2.

Make sure manual shutoff valve is
fully open.

3.

Press in and turn control knob clock-

wise 

Clockwise

 to the OFF position.

Figure 23 - Pilot

OPERATING
HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

PILOT

OFF

LO

HI

Control Knob

Ignitor Button

Figure 22 - Control Knob and Ignitor Button Location

LIGHTING

INSTRUCTIONS

 WARNING:

• If fireplace has glass doors,

never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Also
if fireplace opening has vents
at the bottom, you must open
the vents before operating
heater.

• You must operate this heater

with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Open damper or window to vent
smell. This will only last a few
hours.

Note:

 Homeowners generally prefer to

operate their heater with the chimney
damper closed. This will put all the heat
into the room. However there may be
times you will desire the full flames of the
High heat setting but will find the heat
output excessive. You can open the chim-
ney damper (if you have one) fully or
partially to release some of the heat.

 WARNING: Damper handle

will be hot if heater has been
running.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column 1. If you don’t
smell gas, go to the next step.

5.

Slightly depress and turn control
knob counterclockwise  

C-clockwise

 to

the PILOT position. Keep control
knob pressed in for five (5) seconds
(see Figure 22).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
burner. If needed, keep pressing ig-
nitor button until pilot lights.

Note:

 If pilot does not light, contact

a qualified service person or gas sup-
plier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
 on page 16.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

8.

Slightly depress and turn control
knob counterclockwise  

C-clockwise

 to

the HIGH position. The burner
should light. Set control knob to any
heat level between HIGH and LO.

(

Note: Appearance of pilot assembly may

vary by model.)

Thermocouple

Ignitor
Electrode

Pilot Burner

Continued

MANUALLY CONTROLLED
MODELS

Содержание Flame-Max VYS18P

Страница 1: ...pplier WARNING This appliance has been spe cifically tested and design certified for installation only in a solid fuel burning fireplace including factory built UL127 fireplaces and masonry fireplaces...

Страница 2: ...glass to burst Also if fireplace open ing has vents at the bottom you must open the vents before operating heater 9 You must operate this heater with a fire place screen in place Make sure fire place...

Страница 3: ...heaters The ODS pilot shuts off the heater if there is not enough fresh air Piezo Ignition System This heater has a piezo ignitor This system requires no matches batteries or other sources to light he...

Страница 4: ...d fresh air for proper com bustion and ventilation Exhaustfans fireplaces clothesdryers and fuel burning appliances draw air from the house to operate You must provide ad equate fresh air for these ap...

Страница 5: ...nces Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used __________ Btu Hr maximum the...

Страница 6: ...utdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly t...

Страница 7: ...ore installing in a solid fuel burning fireplace thechimneyflueandfireboxmust be cleaned of soot creosote ashes and loose paint by a quali fied chimney cleaner Creosote will ignite if highly heated A...

Страница 8: ...hick With sheet metal you must have non combus tible material behind it Non combustible materialmustextendatleast8inchesup for all models If non combustible material is less than 12 you must install t...

Страница 9: ...learancesrequired Followminimumclear ances shown in Figure 7 when using hood Minimum Non Combustible Material Minimum Non Combustible Material Height Distances to Underside of Mantel Top of Fireplace...

Страница 10: ...29 sq inches 7 39 sq inches 8 51 sq inches Chimney Minimum Permanent Height ft Flue Opening sq ins 6 to 15 39 sq inches 15 to 30 29 sq inches Figure 10 Attaching Damper Clamp INSTALLING HEATER BASE AS...

Страница 11: ...itting to be threaded into gas regulator Connect approved flex ible gas hose to gas regulator of heater see Figure 11 IMPORTANT Hold gas regulator with wrenchwhenconnectingflexiblegashose 2 Locate two...

Страница 12: ...listed below external regulator supplied by installer piping check local codes sealant resistant to LP gas manual shutoff valve test gauge connection sediment trap tee joint pipe wrench AnA G A design...

Страница 13: ...s from propane supply tank to manual shutoff valve see Fig ure 15 Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 4 Correct all leaks at once Pressure Testing Heater...

Страница 14: ...Back Log 1 Crossover Log 3 Figure 19 Installing Crossover Log Figure 18 Installing Front Log Front Log 2 Notch Peg Notch Rectangular Knob Notch Peg Tabs of Grate Base Hole Rectangular Knob For Golden...

Страница 15: ...ace screen is closed before running heater NOTICE During initial operation of new heater burning logs will give off a paper burning smell Open damper or window to vent smell This will only last a few...

Страница 16: ...to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you c...

Страница 17: ...upplier for repairs 6 With control knob pressed in press and release ignitor button This will light pilot The pilot is attached to the front burner If needed keep press ing ignitor button until pilot...

Страница 18: ...ally clogged ODS pilot 6 Thermocouple connection loose at con trol valve 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or...

Страница 19: ...air is removed from line Have gas line checked by local natural gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burners see Cleaning and Mainte nance page 23 or re...

Страница 20: ...p of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between con...

Страница 21: ...you have a masonry fire place see Figure 31 for location If you have a factory built metal fireplace see Figure 32 for location If your fireplace has glass doors position sensing bulb directly behind...

Страница 22: ...8 0 W C Inlet Gas Pressure in of water Maximum 14 14 14 Minimum 11 11 11 Shipping Weight 36 lbs 38 lbs 26 lbs Golden Oak and Birch 24 30 and 36 Golden Oak Golden Oak Variable 18 Thermostat 24 and 30...

Страница 23: ...rol areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cle...

Страница 24: ...ROPANE LP GAS LOG HEATER VANGUARD FLAME MAX ILLUSTRATED PARTS BREAKDOWN FLAME MAX VINTAGE OAK MODELS VYS18P AND VYS24P 4 1 2 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 22 18 13 19 17 20 18 20 1 20 2 23...

Страница 25: ...1 12 102963 01 102773 01 Burner 1 13 102568 08 102568 08 Control Valve 1 14 098508 01 098508 01 Valve Retainer Nut 1 15 098354 01 098354 01 Control Knob 1 16 102445 01 102445 01 Piezo Ignitor 1 17 09...

Страница 26: ...ARTS BREAKDOWN FLAME MAX GOLDEN OAK AND BIRCH LOG MODELS VYD18P VYBD18P VYD24P VYBD24P VYD30P VYBD30P AND VYD36P 4 20 10 11 12 20 7 20 20 5 6 9 8 15 14 16 18 2 17 13 18 3 19 17 1A 1B Note The Golden O...

Страница 27: ...Burner Clip 1 12 102980 01 102980 01 102772 01 102772 01 102772 01 102772 01 102772 01 Burner 1 13 102568 08 102568 08 102568 06 102568 06 102568 06 102568 06 102568 06 Control Valve 1 14 098508 01 0...

Страница 28: ...UNVENTED PROPANE LP GAS LOG HEATER VANGUARD FLAME MAX ILLUSTRATED PARTS BREAKDOWN THERMOSTATICALLY CONTROLLED MODELS VYD18PT VYD24PT VYD30PT 12 1 2 18 16 17 20 10 9 5 11 4 7 6 19 8 21 13 19 14 19 19 3...

Страница 29: ...102843 01 102843 01 102843 01 Burner Clip 1 11 102980 01 102772 01 102772 01 Burner 1 12 101329 22 101329 19 101329 19 Thermostat Gas Valve Assembly 1 13 102979 02 102979 01 102979 01 Thermostat Brac...

Страница 30: ...ckfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier TECHNICAL SERVICE You may have further questions about in stallation operation o...

Страница 31: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 32: ...the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper m...

Отзывы: